Laurel Electronics
Marca +52 (444) 548 2052 para Asistencia en México

ventas@laurelsmexico.com
Panel Meters - Counters - Timers - Transmitters, 4-20 mA & Modbus - Ethernet - USB - RS485 - RS232

4-20 mA & Serial Data Transmitter for AC RMS Voltage or Current

Responds in 1 power line cycle response with 0.1% accuracy. DIN Rail mounted, digitally programmable.

AC RMS transmitter

Standard Features

  • 4-20 mA, 0-20 mA, 0-10V or -10V to +10V transmitter output, 16 bits, isolated
  • RS232 or RS485 serial data output, Modbus or Laurel ASCII protocol, isolated
  • Dual 120 mA solid state relays for alarm or control, isolated
  • True AC RMS measurement in one 50/60 Hz AC line cycle
  • 0.2, 2, 20, 200, 300V and 600V AC voltage ranges
  • 2, 20, 200 mA and 5A AC current ranges
  • All input ranges user-selectable and factory calibrated
  • AC or DC coupling for signals from DC to 10 kHz
  • Measurements from 0% to 100% of full scale
  • 0.03% accuracy of full scale at crest factor to 3.0
  • Universal 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac power
  • -X extended temperature option from -40°C to 70°C
Description

The Laureate 4-20 mA and RS232/RS485 output, AC RMS input transmitter provides six voltage input ranges and four current input ranges, all factory calibrated and jumper selectable. A special 5.000A range utilizes a built-in 0.01 ohm shunt resistor to accept the output of 5A current transformers, with no need for a stepdown transformer. The current readings can be scaled digitally as needed. High common mode rejection allows stable readings with current shunts located on the high side of the line. Digital filtering is selectable for noisy signals.

LT transmitter AC

True RMS precision circuitry is used to determine the root-mean-square of complex waveforms from DC to 10 kHz. Spikes up to 3.0 times the maximum of each range are accurately measured.

Accuracy is 0.03% of full scale for the transmitters with 1 Megohm input resistance, signals from DC to 10 kHz, and signal amplitude down to 0. The crest factor (Vp / Vrms) is 3.0 at full scale, increasing to 300 for a signal amplitude of 1% of full scale. A version with 10 Megohm input resistance is available as a factory special, but decreases the maximum frequency from 10 kHz to 1 kHz for three of the voltage ranges.

True RMS readings in as little as one 50/60 Hz AC line cycle are unmatched in the industry. Such a high read rate allows anomalies to be detected and alarmed before they become expensive problems. On/off control and alarm can be achieved dual solid state relays, which are standard. Transmitter can also capture peak and valley for times as short as one 50/60 Hz AC power line cycle.

Standard features of Laureate LT transmitters include:

  • 4-20 mA, 0-10V or -10V to +10V analog transmitter output, isolated, jumper-selectable and user scalable. All selections provide 16-bit (0.0015%) resolution of output span and 0.02% output accuracy of a reading from -99,999 to +99,999 counts that is also transmitted digitally. Output isolation from signal and power grounds eliminates potential ground loop problems.
  • Serial communications output, RS232 or RS485 (half or full duplex), jumper selectable. Three protocols are user selectable: Modbus RTU, Modbus ASCII, or Laurel ASCII. Modbus operation is fully compliant with Modbus Over Serial Line Specification V1.0 (2002). The Laurel ASCII protocol is simpler than the Modbus protocol and is recommended when all devices are Laureates.
  • Dual solid state relays, isolated, for alarm or control. Rated 120 mA at 130 Vac or 180 Vdc.
  • Universal 85-264 Vac power. Low-voltage 10-48 Vdc or 12-32 Vac power is optional.
  • AC or DC coupling is jumper selectable. AC coupling is suitable for applications such as measuring the ripple on a DC power supply. Multiple integral cycles are averaged for signals above 50/60 Hz. A single cycle is captured for signals from 3 Hz to 50/60 Hz. Below 3 Hz and at DC, the capture rate is every 333 ms.

Easy Transmitter programming is via Laurel's Instrument Setup Software, which runs on a PC under MS Windows. This software can be downloaded from this website at no charge. The required transmitter-to-PC interface cable is available from Laurel (P/N CBL04).

Specifications
Laureate 4-20 mA and RS232/RS485 Transmitter for AC RMS Voltage or Current Input
Analog Input Range Resolution Input Ohms
Error at 25°C
Voltage Ranges
0-100% of FS
10 Hz - 10 kHz (AC coupling)
DC - 10 kHz (DC coupling)
200.00 mV 10 µV 1 MΩ 0.03% FS ± 2 cts
2.0000 V 100 µV 1 MΩ 0.03% FS ± 2 cts
20.000 V 1 mV 1 MΩ 0.03% FS ± 2 cts
200.00 V 10 mV 1 MΩ 0.03% FS ± 2 cts
600.0 V* 100 mV 1 MΩ ± 0.8 V
300.0 V 100 mV 1 MΩ ± 0.8 V
Current Ranges
0-100% of FS
10 Hz - 10 kHz (AC coupling)
DC - 10 kHz (DC coupling)
2.0000 mA 0.1 µA 100 Ω 0.03% FS ± 2cts
20.000 mA 1 µA 10 Ω 0.03% FS ± 2cts
200.00 mA 10 µA 1 Ω 0.03% FS ± 2cts
5.000 A 1 mA 0.01 Ω ± 20 mA
* Range not ETL certified
Analog Output (standard)
Output Levels 4-20 mA, 0-20 mA, 0-10 Vdc, -10 to +10 Vdc (user selectable)
Compliance, 20 mA 10V (0-500Ω load)
Compliance, 0-10V 2 mA (5 kΩ load)
Output Resolution 16 bits (65,536 steps)
Output Accuracy 0.02% of output span plus conversion accuracy
Output Isolation 250V rms working, 2.3 kV rms per 1 minute test
Serial Data Output (standard)
Type RS232 or RS485 (half or full duplex), jumper selectable
Data Rates 300, 600, 1200, 2400, 4800, 9600, 19200 baud
Output Isolation 250V rms working, 2.3 kV rms per 1 min test
Serial Protocols Modbus RTU, Modbus ASCII, Custom ASCII
Modbus Compliance Modbus over Serial Line Specification V1.0 (2002)
RS232/RS485 Connector Screw terminals for easy daisy chaining
Digital Addresses 247 for Modbus, 31 for Custom ASCII
Dual Relay Output (standard)
Relay Type Two solid state relays, SPST, normally open, Form A
Load Rating 120 mA at 140 Vac or 180 Vdc
Power Input
Standard Power 85-264 Vac or 90-300 Vdc
Low Power Option 10-48 Vdc or 12-32 Vac
Power Frequency DC or 47-63 Hz
Power Isolation 250V rms working, 2.3 kV rms per 1 min test
Power Consumption at 24V 1.5W typical
Mechanical
Dimensions 129 x 104 x 22.5 mm case
Mounting 35 mm rail per DIN EN 50022
Electrical Connections Plug-in screw-clamp connectors
Environmental
Operating Temperature 0°C to 55°C standard, -40°C to 70°C with -X option
Storage Temperature -40°C to 85°C
Relative Humidity 95% at 40°C, non-condensing
Cooling Required Mount transmitters with ventilation holes at top and bottom. Leave 6 mm (1/4") between transmitters, or force air with a fan.
*   For purposes of accuracy calculation, the 600V range is 2000V (20,000 counts), and the 5A range is 20A (20,000 counts).
Pinout
Laureate LT transmitter pinout
For applications assistance, phone 714-434-6131 ext. 104, or email support@laurels.com
Ordering Guide
Laureate 4-20 mA & RS232/RS485 Data Transmitter for AC RMS Voltage or Current Input
Click on the radio buttons to build a model number with pricing as shown below. Prices are in US dollars and do not include shipping or duty charges (export sales). Please see our explanations and limitations applicable to pricing and online orders. Prices shown are in US Dollars and are Laurel's manufacturer's suggested retail price (MSRP) in the USA. Orders are processed manually, not directly by our shopping cart system. You don't have to supply credit card information when placing an online order.

North American Orders. Laurel does not sell factory-direct in the USA or Canada. Online sales orders are filled through distribution. During the ordering process, you will have the chance to select an authorized Laurel distributor, or you can ask Laurel to refer you to a distributor. The distributor will then contact you to quote shipping, tax and duty (where applicable), and arrange for payment.

International Orders. If your ship-to address indicates that you are outside of the USA or Canada and Laurel has a distributor in your country, we will forward your order to that distributor for follow-up. If Laurel does not have a distributor in your country, we will email you an order acknowledgment and a pro forma invoice which states the product price, shipping charges, and wire transfer information, which includes a $25 bank wire transfer fee.

Questions about your order? Please email your distributor or ventas@laurelsmexico.com
 
Quantity
Transmitter Type LT  4-20 mA & RS232/RS485 output transmitter $164
LTE  4-20 mA & Ethernet output transmitter $388
Main Board 2  Standard analog input. $0
4  Extended analog input. $33
Note:Extended allows custom curve linearization and rate from successive readings. Not applicable to temperature.  
Power 0  Isolated 85-264 Vac or 90-300 Vdc $89
1  Isolated 12-32 Vac or 10-48 Vdc $89
Signal Input True AC RMS Volts  
RMV1  200.00 mV $135
RMV2  2.0000 V $135
RMV3  20.000 V $135
RMV4  200.00 V $135
RMV5  600.0 V (range not ETL certified) $135
RMV6  300.0 V (range ETL certified) $135
True AC RMS Amps  
RMA1  2.0000 mA $135
RMA2  20.000 mA $135
RMA3  200.00 mA $135
RMA4  5.000 A $135
Note:  The same AC RMS signal conditioner can be user configured for AC Volts or AC Amps, and is precalibrated in EEPROM for all AC Volt and AC Amp ranges listed.  
Add-on Options -X  Extended operating temperature option from -40°C to 70°C $33
CBL04  RS232 cable, 7ft. Connects RS232 screw terminals of LT transmitter to DB9 port of PC. $23
CBL02  USB-to-DB9 adapter cable. Includes FTDI chip for compatibility with all versions of Windows. Combination of CBL02 and CBL04 connects PC USB port to LT RS232 port. $47
 
Configured model number LT20RMV1
Configured price per model $388
Quantity 1
Extended price $388
Legal Information
seal-20th24    
facebook   G+   twitter   linkedin
© 1990-2024 Laurel Electronics
feedback