Panel Meters - Counters - Timers - Transmitters, 4-20 mA & Modbus - Ethernet - USB - RS485 - RS232

Ethernet & 4-20 mA Output Transmitter for DC Voltage or Current

DIN rail mounted, digitally programmable. Includes two relays for alarm or control. Exceptional accuracy at high update rates.

Ethernet transmitter

Features

  • Ethernet data I/O, Modbus TCP.
  • 4-20 mA, 0-20 mA or 0-10V transmitter output, 16 bits, jumper selectable, isolated.
  • Dual 120 mA solid state relays for alarm or control, isolated.
  • 5V, 10V or 24V dc transducer excitation output, isolated.
  • ±0.2, ±2, ±20, ±200, ±300V and ±600V voltage input ranges.
  • ±2, ±20, ±200 mA and ±5A current input ranges.
  • Analog output resolution 0.0015% of span (16 bits), accuracy ±0.02% of span.
  • Universal 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac power.
  • Custom curve linearization and rate from successive readings (optional).
  • DIN rail mount housing only 22.5 mm wide, detachable screw-clamp connectors.
  • -X extended operating temperature option from -40°C to 70°C
Description

The Laureate DC input transmitter provides six voltage input ranges and four current input ranges, all factory calibrated and jumper selectable. The 200.00 mV and 2.0000 V ranges provide a high input impedance of 1 GΩ to minimize the load on the voltage signal. A 5.000A range measures the IR drop across a built-in 10 mΩ current shunt. The transmitters can also easily be scaled in software for use with external shunts.

Fast read rate at up to 50 or 60 conversions per second while integrating the signal over a full power line cycle is provided by Concurrent Slope (Pat 5,262,780) analog-to-digital conversion. High read rate is ideal for peak or valley capture and for real-time computer interface and control.

Digital signal filtering modes are selectable for stable readings in electrically noisy environments.

  • An unfiltered selection provides true peak and valley readings and aids in control applications.
  • A batch average filter selection averages each 16 conversions for an update every 1/4 sec.
  • Dual solid state relays for control or alarm, isolated. Rated 120 mA at 140 Vac or 180 Vdc. The relays can respond to digital readings or to received control characters.
  • An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 s. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.

Standard features of Laureate LTE transmitters include:

  • Ethernet I/O, isolated. The supported protocols are Modbus RTU and ASCII, which are tunneled via Modbus TCP. Note that RS232 or RS485 data I/O is provided by Laurel's LT Series transmitters.
  • 4-20 mA, 0-20 mA or 0-10V analog transmitter output, isolated, jumper-selectable and user scalable. All selections provide 16-bit (0.0015%) resolution of output span and 0.02% output accuracy of a reading from -99,999 to +99,999 counts that is also transmitted digitally. Output isolation from signal and power grounds eliminates potential ground loop problems. The supply can drive 20 mA into a 500 ohm (or lower) load for 10V compliance, or 10V into a 5K ohm (or higher) load for 2 mA compliance.
  • Dual solid state relays, isolated. Available for local alarm or control. Rated 120 mA at 130 Vac or 180 Vdc.
  • Universal 85-264 Vac power. Low-voltage 10-48 Vdc or 12-32 Vac power is optional.

Node discovery and configuration of Laureate Ethernet transmitters are easily achieved with Laurel's Windows based Instrument Setup Software. Additional features are provided by Laurel's Windows based Node Manager Software, such as the ability to send emails or test messages either periodically or in the event of an alarm. Both softwares run on a PC under MS Windows, are at no charge, and can be downloaded from this website.

Laureate Ethernet network by Laurel Electronics
Specifications
Laureate™ Ethernet & 4-20 mA Transmitter for DC Voltage or Current Input
Analog Input Range Resolution Accuracy Input Ohms
DC Voltage ±200.00 mV 10 µV 0.01% FS ± 2 cts 1 GΩ
±2.0000 V 100 µV 0.01% FS ± 2 cts 1 GΩ
±20.000 V 1 mV 0.01% FS ± 2 cts 10 MΩ
±200.00 V 10 mV 0.01% FS ± 2 cts 10 MΩ
±600.0 V* 100 mV ± 0.4 V 10 MΩ
DC Current ±2.0000 mA 0.1 µA 0.01% FS ± 2 cts 100 Ω
±20.000 mA 1 µA 0.01% FS ± 2 cts 10 Ω
±200.00 mA 10 µA 0.01% FS ± 2 cts 1 Ω
±5.000 A 1 mA ±10 mA 0.01 Ω
* Range ETL certified to ±300.0 V
Input Resolution 16 bits (65,536 steps)
Update Rate, Max 50/sec at 50 Hz, 60/sec at 60 Hz
Max applied voltage 600 Vac for 20, 200 & 600 V ranges, 125 Vac other ranges
Over-current protection 25x for 2 mA, 8x for 20 mA, 2.5x for 200 mA, 1x for 5 A
Analog Output (standard)
Output Levels 0-20 mA or 0-10 Vdc (selectable)
Compliance, 4-20 mA 10V (0-500Ω load)
Compliance, 0-10V 2 mA (5 kΩ load)
Output Resolution 16 bits (65,536 steps)
Output Accuracy 0.02% of output span plus conversion accuracy
Output Isolation 250V rms working, 2.3 kV rms per 1 minute test
Ethernet Data I/O (standard)
Type 10/100 Base-T Ethernet per IEEE 802.3
Data Rates 300, 600, 1200, 2400, 4800, 9600, 19200 baud
Output Isolation 250V rms working, 2.3 kV rms per 1 min test
Serial Protocols Modbus TCP
Modbus Compliance Modbus over Serial Line Specification V1.0 (2002)
Digital Addresses 247
Dual Relay Output (standard)
Relay Type Two solid state relays, SPST, normally open, Form A
Load Rating 120 mA at 140 Vac or 180 Vdc
Transducer Excitation Output (standard)
Output Levels 5V@100 mA, 10V@120 mA, 24V@50 mA (jumper selectable)
Output Isolation 50V from signal ground
Transducer Excitation Output (standard)
Output Levels 5V@100 mA, 10V@120 mA, 24V@50 mA (jumper selectable)
Output Isolation 50V from signal ground
Power Input
Standard Power 85-264 Vac or 90-300 Vdc
Low Power Option 10-48 Vdc or 12-32 Vac
Power Frequency DC or 47-63 Hz
Power Isolation 250V rms working, 2.3 kV rms per 1 min test
Power Consumption 2.5W typical at 24V, 4.0W with max excitation output
Mechanical
Dimensions 129 x 104 x 22.5 mm case
Mounting 35 mm rail per DIN EN 50022
Connectors Detachable screw-clamp connectors for signal and power RJ45 jack for Ethernet
Environmental
Operating Temperature 0°C to 55°C standard, -40°C to 70°C with -X option
Storage Temperature -40°C to 85°C
Relative Humidity 95% at 40°C, non-condensing
Cooling Required Mount transmitters with ventilation holes at top and bottom. Leave 6 mm (1/4") between transmitters, or force air with a fan.
Pinout
Laureate™ Ethernet & 4-20 mA Transmitter for DC Voltage or Current Input Pinout for Laureate LTS serial-to-analog transmitter
For applications assistance, phone 714-434-6131 ext. 104, or email support@laurels.com
Ordering Guide
Laureate™ Ethernet & 4-20 mA Transmitter for DC Voltage or Current Input
Click on the radio buttons to build a model number with pricing as shown below. Prices are in US dollars and do not include shipping or duty charges (export sales). Please see our explanations and limitations applicable to pricing and online orders. Prices shown are in US Dollars and are Laurel's manufacturer's suggested retail price (MSRP) in the USA. Orders are processed manually, not directly by our shopping cart system. You don't have to supply credit card information when placing an online order.

North American Orders. Laurel does not sell factory-direct in the USA or Canada. Online sales orders are filled through distribution. During the ordering process, you will have the chance to select an authorized Laurel distributor, or you can ask Laurel to refer you to a distributor. The distributor will then contact you to quote shipping, tax and duty (where applicable), and arrange for payment.

International Orders. If your ship-to address indicates that you are outside of the USA or Canada and Laurel has a distributor in your country, we will forward your order to that distributor for follow-up. If Laurel does not have a distributor in your country, we will email you an order acknowledgment and a pro forma invoice which states the product price, shipping charges, and wire transfer information, which includes a $25 bank wire transfer fee.

Questions about your order? Please email your distributor or ventas@laurelsmexico.com
 
Quantity
Transmitter Type LTE  4-20 mA & Ethernet outputs transmitter $388
LT  4-20 mA & RS232/RS485 outputs transmitter $164
Main Board 2  Standard analog input. $0
4  Extended analog input. $33
Note:Extended allows custom curve linearization and rate from successive readings. Not applicable to temperature.  
Power 0  Isolated 85-264 Vac or 90-300 Vdc $89
1  Isolated 12-32 Vac or 10-48 Vdc $89
Signal Input DC Volts  
DCV1  ± 200.00 mV $81
DCV2  ± 2.0000 V $81
DCV3  ± 20.000 V $81
DCV4  ± 200.00 V $81
DCV5  ± 600.0 V (range not ETL certified) $81
DCV6  ± 300.0 V (range ETL certified) $81
DC Amprs  
DCA1  ± 2.0000 mA $81
DCA2  ± 20.000 mA $81
DCA3  ± 200.00 mA $81
DCA4  ± 5.000 A $81
Note:  The same DC signal conditioner can be user configured for DC Volts or DC Amps, and for process, strain or potentiometer follower signals. It is precalibrated in EEPROM for all DC Volt and DC Amp ranges listed.  
Add-on Options -X  Extended operating temperature option from -40°C to 70°C $33
 
Configured model number LTE20DCV1
Configured price per model $558
Quantity 1
Extended price $558
Legal Information
seal-20th24    
facebook   G+   twitter   linkedin
© 1990-2024 Laurel Electronics