Panel Meters - Counters - Timers - Transmitters, 4-20 mA & Modbus - Ethernet - USB - RS485 - RS232

Laureate™ Load Cell, Strain Gauge & Microvolt Digital Panel Meter

20 mV - 500 mV full-scale ranges, 4- or 6-wire connection

Load cell meter by Laurel Electronics

Features

  • 20, 50, 100, 250 & 500 mV full scale ranges, 1 microvolt sensitivity
  • Zero adjust from -99,999 to +99,999, span adjust from 0 to ±99,999
  • Accuracy of 0.01% of reading ± 2 counts
  • Up to 60 conversions per second
  • Isolated 10 Vdc excitation to power four 350-ohm load cells in parallel
  • 4- or 6-wire hookup to avoid lead resistance effects
  • Universal 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac power
  • Wide choice of options:
    - 2 or 4 relays, mechanical or solid state (isolated)
    - Analog output, 4-20 mA, 0-10V, or -10V to +10V (isolated)
    - Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)
    - Custom curve linearization, rate from consecutive readings
  • -X extended temperature option from -40°C to 70°C
Description
dc-panel-meter

The Laureate™ load cell, strain gauge and microvolt meter is a 5-digit panel meter with exceptionally high accuracy and stability for use with low-level signals.

  • Load cell meter operation provides sensitivity down to ±20 mV full scale for use with 2 mV/V load cells at 10V excitation. Ratiometric operation automatically compensates for changes in excitation. The 5 digit display can be scaled for direct readout in engineering units, such as pounds, kilograms or PSI. Scaling can be via front panel pushbuttons or a computer. Zero may be set from -99,999 to +99,999. Range may be scaled from 0 to ±99,999. Digital scaling and calibration eliminate drift caused by potentiometers in non-microcomputer based meters.
  • DC microvoltmeter operation provides sensitivity down to ±20.000 mV full scale with 1 µV resolution for use with 2 mV/V load cells. A display span of 99,999 counts with sensitivity of 0.2 µV per count can be obtained by applying a digital multiplier of five. A moving average digital filter assures quiet readings in electrically noisy environments.

Meter accuracy in ratiometric bridge operation is 0.01% of reading ± 2 counts. Custom curve linearization, which is available with the optional Extended main board, can extend the working range of load cells. Custom curve linearization also allows greater accuracy to be achieved with lower cost, less linear load cells.

A built-in isolated excitation supply can provide up to 120 mA of current at 10V to power four 350-ohm load cells in parallel. The meter operates in a ratiometric mode to eliminate errors due to supply variations. When excitation sense inputs are used in 6-wire connection, the meter compensates for variation in resistance of the transducer leads, thereby allowing long cable runs.

High read rates at up to 60 or 50 conversions per second while integrating the signal over a full power cycle are provided by Concurrent Slope (US Pat 5,262,780) analog-to-digital conversion. High read rates are ideal for peak or valley capture, real-time computer interface, and control.

Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.

Load cell signal conditioner board for Laurel digital panel meter Digital filtering is selectable for electrically noisy environments, including a batch averaging filter and an adaptive moving average filter which provides a choice of 8 time constants from 80 ms to 9.6 s. When a significant change in signal level occurs, that filter adapts by briefly switching to the shortest time to follow the change, then reverts back to the selected time constant. In a selectable Auto filter mode, the filter time constant is automatically selected based on detected signal noise.

Scale and offset can be provided by either of two user-selectable methods:

  • With the coordinate reading method, the meter reads the high and low signal values, and the user enters the desired high an low reading values. The meter then calculates the span multiplier and offset. This method is ideal if an external calibration reference is available.
  • With the manual coordinate method, the user enters the high and low input values in Volts plus the desired high and low reading values. This method is suitable if no external calibration reference is available.

Auto-tare is standard for weighing applications to subtract the weight of an empty container and may be controlled by an external pushbutton contact closure or a logic signal. Additional capabilities for weighing applications are provided by the Laureate weight & scale meter.

Designed for system use. Optional plug-in boards for communications and control include Ethernet, WiFi and serial communication boards, dual or quad relay boards, and an isolated analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with red or green LEDs. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in isolated 5, 10, or 24 Vdc excitation supply can power transducers and eliminate the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.

Load Cell Meter Connections

In 4-wire connection, the excitation and sense lines are tied together. The meter can make ratiometric corrections for supply voltage variations, but not compensate for variations in lead resistance. This connection is often used with short cable runs.
In 6-wire connection, the sense lines are separate from the excitation lines, thereby eliminating effects due to variations in lead resistance. This allows long cable runs in outdoor environments with temperature extremes.
For large scales, up to four 350 ohm load cells can be powered by a single Laureate, whose excitation output is rated 120 mA at 10V. The excitation and sense points of the four bridges are connected in parallel. The load cell outputs will be averaged if the load cells have the same sensititivity in mV/V.

Seat belt tensile strength testing using Laureate digital panel meters.
The three meters display Force, Displacement and Speed.

Specifications

DC Microvoltmeter Inputs

Input Range mV Resolution Input Resistance Error at 25°C
±20.000 1 µV 1 GΩ ±0.01% of full scale
±2 counts
±50.000 1 µV
±100.00 10 µV
±250.00 10 µV
±500.00 10 µV

Load Cell Inputs

Full-Scale Input, mV Zero Adjust Span Adjust Input Resistance Error at 25°C
±20.00 0 to ±99,999 1 GΩ ±0.01% of reading
±2 counts
±50.00 -99,999
±100.00 to
±250.00 +99,999
±500.00

DC Microvolts & Load Cell Inputs

Accuracy
Error at 25°C ±0.01% of reading ± 2 counts in ratiometric mode,
±0.01% of full scale ± 2 counts in absolute mode.
Span tempco 0.0015% of reading/°C
Zero tempco 0.1 µV/°C
Load cell linearization Programmable using Extended meter version
Noise Rejection
CMR, DC to 60 Hz 130 dB
NMR at 50/60 Hz 90 dB with min filtering
A-to-D Conversion
Technique Concurrent Slope™ (Pat 5,262,780)
A-to-D rate 60/s at 60 Hz, 50/s at 50 Hz
Output update rate 56/s at 60 Hz, 47/s at 50 Hz
Display update rate 3.5/s at 60 Hz, 3/s at 50 Hz
Display
Readout 5 LED digits, 7-segment, 14.2 mm (.56"), red or green
Range -99999 to 99999 or -99990 to 99990 (count by 10)
Indicators Minus sign, 2 red LED lamps
Power Supply Boards (one required)
Voltage, standard 85-264 Vac or 90-300 Vdc
Voltage, optional 12-32 Vac or 10-48 Vdc
Frequency DC or 47-63 Hz
Power  consumption (typ. with four 350Ω load cells at 10V) 2.4W @ 120 Vac, 2.7W @ 240 Vac, 2.5W @ 10 Vdc, 2.6W @ 20 Vdc, 2.75W @ 30 Vdc, 3.0W @ 40 Vdc, 3.35W @ 48 Vdc
Power Isolation 250V rms working, 2.3 kV rms per 1 min test
Excitation Output (standard)
5 Vdc 5 Vdc ± 5%, 100 mA
10 Vdc 10 Vdc ± 5%, 120 mA
24 Vdc 24 Vdc ± 5%, 50 mA
Output Isolation 50 Vdc to meter ground
Ratiometric operation Automatically compensates for changes in excitation level.
Analog Output Board (one optional)
Output levels 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (jumper selectable)
Current compliance 20 mA at 10V ( > 5 kΩ load)
Voltage compliance 12V at 20 mA (< 600 Ω load)
Scaling Zero and full scale adjustable from -99999 to +99999
Resolution 16 bits (0.0015% of full scale)
Isolation 250V rms working, 2.3 kV rms per 1 min test
Relay Output Boards (one optional)
Dual magnetic relays 2 Form C, 8A at 250 Vac or 24 Vdc, 0.3A at 250 Vdc, resistive load
Quad magnetic relays 4 Form A (NO), 8A at 250 Vac or 24 Vdc, 0.3A at 250 Vdc, resistive load
Dual solid state relays 2 Form A (NO), 120 mA at 140 Vac or 180 Vdc, resistive load
Quad solid state relays 4 Form A (NO), 120 mA at 140 Vac or 180 Vdc, resistive load
Relay commons Isolated commons for dual relays or each pair of quad relays
Relay isolation 250V rms working, 2.3 kV rms per 1 minute test
Relay latching modes Latching or non-latching
Relay active modes Active on or off, active high or low
Hysteresis modes QA passband mode, split hysteresis, span hysteresis
Communication Boards (one optional)
Board selections RS232RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, Ethernet, USB-to-RS485 gatewayEthernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485
Protocols Laurel Custom ASCII (serial), Modbus RTU (serial), Modbus TCP (Ethernet or WiFi)
Digital addresses 247 (Modbus), 31 (Laurel ASCII),
Isolation 250V rms working, 2.3 kV rms per 1 min test
Signal Connections
Environmental
Operating temperature 0°C to 55°C standard, -40°C to 70°C with -X option
Storage temperature. -40°C to 85°C
Relative humidity 95% at 40°C, non-condensing
Protection NEMA-4X (IP-65) when panel mounted
Applications

Sample Load Cell Meter Applications

Auto-Tare To read the net weight of an object, the empty container is first weighed, and an external button is pushed to zero out the display. The meter will then read net weight when an object is added to the empty container. The tare value is stored in memory for subsequent readings.
Determining Volume Using Load Cells An easy way to determine volume of an irregularly shaped tank with no need for linearizing is to weigh the tank using load cells. The meter will automatically tare out the weight of the empty tank and then scale the load cell signals to units of volume, such as liters or gallons.
Capture for Tensile Strength of Wire Peak readings are automatically captured at rates up to 60 per second, while the display updates at a legible 3.5 per second. The peak reading can be recalled at the push of a button or be always displayed. It can also be transmitted to a computer via RS232, RS485, USB or Ethernet.
For applications assistance, phone 714-434-6131 ext. 104, or email support@laurels.com
Ordering Guide
Laureate™ Load Cell, Strain Gauge & Microvolt Panel Meter
Click on the radio buttons to build a model number with pricing (shown below the Ordering Guide). Prices are in US dollars and do not include shipping or duty charges (export sales). Please see our explanations and limitations applicable to pricing and online orders. Prices shown are in US Dollars and are Laurel's manufacturer's suggested retail price (MSRP) in the USA. Orders are processed manually, not directly by our shopping cart system. You don't have to supply credit card information when placing an online order.

North American Orders. Laurel does not sell factory-direct in the USA or Canada. Online sales orders are filled through distribution. During the ordering process, you will have the chance to select an authorized Laurel distributor, or you can ask Laurel to refer you to a distributor. The distributor will then contact you to quote shipping, tax and duty (where applicable), and arrange for payment.

International Orders. If your ship-to address indicates that you are outside of the USA or Canada and Laurel has a distributor in your country, we will forward your order to that distributor for follow-up. If Laurel does not have a distributor in your country, we will email you an order acknowledgment and a pro forma invoice which states the product price, shipping charges, and wire transfer information, which includes a $25 bank wire transfer fee.

Questions about your order? Please email your distributor or ventas@laurelsmexico.com
 
Quantity
Main Board L  Laureate Series meter, plug-in screw terminal connectors $157
Display Color 1  Basic DPM with green LEDs. $0
2  Basic DPM with red LEDs. $0
3  Extended DPM with green LEDs. $33
4  Extended DPM with red LEDs. $33
  “Extended” allows custom curve linearization and rate from successive readings. Not applicable to temperature.  
Power 0  Isolated 85-264 Vac or 90-300 Vdc $75
1  Isolated 12-32 Vac or 10-48 Vdc $115
Relay
Output
(isolated)
0  None $0
1  Two 8A Contact Relays $101
2  Two 120 mA Solid State Relays $70
3  Four 8A Contact Relays $128
4  Four 120 mA Solid State Relays $96
Analog
Output
(isolated)
0  None $0
1  Isolated 4-20 mA, 0-20 mA, 0-10 V, -10 to +10V $115
Data
Interface
(isolated)
0  None $0
1  RS232 (L232) $81
2  RS485 (L485, dual RJ11 connectors) $109
4  RS485 (LMOD, dual RJ45 connectors, not for new design) $135
5  USB (LUSB) $81
6  USB-to-RS485 gateway (LUSB485) $135
7  Ethernet (LNET) $237
8  Ethernet-to-RS485 gateway (LNET485) $259
A  Ethernet + USB (LNET1) $182
B  Ethernet + RS485 (LNET1485) $204
C  WiFi + USB internal antenna (LWIFI) $171
D  WiFi + USB, external antenna (LWIFIX) $193
E  WiFi + USB + RS485, internal antenna (LWIFI485) $204
F  WiFi + USB + RS485, external antenna (LWIFIX485) $226
Signal
Input
(isolated)
WM  Field Scalable. Default scaling is 0-20 mV = 0-100.00
WM1  Load cells (4 or 6-wire, ratiometric). Custom scaling.
Specify min signal and displayed reading, max signal and displayed reading. 20-500 mV. Default excitation of 10V for up to four 350-ohm load cells in parallel.
$164
Add-on
Options
-X  Extended operating temperature option from -40°C to 70°C $33
CBL01  RS232 cable, RJ11 to DB9, 7 ft. Connects RS232 ports of meter and PC. $23
CBL02  USB to RS232 adapter cable. Combination of CBL02 and CBL01 connects meter RS232 port to PC USB port. Combination of CBL02 and CBL04 connects transmitter RS232 terminals to PC USB port. $47
CBL03-1  6-wire data cable, RJ11 to RJ11, 1 ft. Used to daisy chain meters via RS485. $10
CBL03-7  6-wire data cable, RJ11 to RJ11, 7 ft. Used to daisy chain meters via RS485. $10
CBL05  USB cable, A-B. Connects USB ports of meter and PC. $19
CBL06  USB to RS485 adapter cable, half duplex, RJ11 to USB. Connects meter RS485 port to PC USB port. $47
CASE1  Benchtop Laboratory Case for One 1/8 DIN Meter $140
CASE2  Benchtop Laboratory Case for Two 1/8 DIN Meters $140
NL  Meter Lens with Button Pads but no Laurels Logo $5
BL  Meter Lens without Button Pads or Laurels Logo $5
IPC  Splash-proof Cover $48
BOX1  NEMA-4 Enclosure $169
BOX2  NEMA-4 Enclosure plus IPC $218
 
Configured model number L10000WM1
Configured price per model $396
Quantity 1
Extended price $396