Features
- Times single or cumulative events from 1 µs to 999,999 hrs
- Transmits single event time or accumulated time of all events
- Timing resolution to 0.2 µs
- Timing from 0.2 µs to 999,999 hrs
- Selectable HH.MM.SS clock format or 6-digit H, M or S decimal format
- Inputs from NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC inputs up to 250 Vac
- Triggers on positive or negative pulse edges
- Digital span adjust from 0 to ±999,999, zero adjust from -999,999 to +999,999
- Front panel scalable: to ±999,999 for use with current shunts
- 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
- Transducer excitation output, 5, 10, 12, or 24 Vdc (isolated)
- Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
- Operating temperature from -40°C to 70°C (-40°F to 158°F)
- Wide choice of Plug-in-Play options:
- 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
- 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
- Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)
- Extended DPM includes rate and total simultaneously, dynamic up-down counting, arithmetic functions
The Laureate™ 1/8 DIN Panel Meter, 6-digit digital stopwatch and timer
can record single or cumulative events ranging from 1 µs to 999,999 hours, with a timing resolution as precise as 0.2 µs. It offers selectable time display formats in HH:MM:SS or 6-digit H, M, or S decimal format, accommodating a variety of measurement needs. Compatible with inputs from NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups as low as 12 mV, and AC inputs up to 250 Vac, it triggers on both positive and negative pulse edges. The device operates on a broad power range of 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac with (isolated) transducer excitation output. It functions reliably in temperatures from -40°C to 70°C. Additionally, it offers a wide range of options including 2 or 4 relays (mechanical or solid-state, (isolated)), 1 or 2 analog outputs (isolated), and various communication interfaces such as Ethernet, WiFi, USB, RS232, and RS485 (isolated).- A-A Stopwatch Mode. Time can be measured between a start pulse and a stop pulse, both on Channel A, from either the positive or negative edges.
- A-B Stopwatch Mode. Time can also be measured between a start pulse on Channel A (positive or negative edge) and a stop pulse on Channel B (positive or negative edge). This mode allows inputs from different sources. In addition, the A and B inputs can be tied together to start the stopwatch with one polarity and stop it with the other polarity.
- Rate Based on 1/Time Mode. Highly accurate rate can be displayed by taking the inverse of time. Extensive arithmetic capabilities allow display in engineering units, such as meter/sec. This mode requires use of an Extended counter.
Display. The event time (Item #1) may be displayed as a decimal number with six-digit resolution. The longest single-event timing interval is 999,999 hours. The highest resolution is 0.2 µs. The event time may also be displayed in HH.MM.SS clock format with 1 s resolution. The stopwatch display is updated during timing at a rate controlled by a gate time, up to 25/s. It is reset to zero when the next start pulse occurs. Accumulated time from multiple events (Item #2) is also tracked and may be displayed up to 999,999 hours.
The FR dual-channel signal conditioner board accepts inputs from proximity switches with a PNP or NPN output, TTL or CMOS logic, magnetic pickups, contact closures, and other signals from 12 mV to 250 Vac. Jumper selections provide optimum operation for different sensor types and noise conditions. A built-in (isolated) 5, 10, 12, or 24 Vdc excitation supply can power proximity switches and other sensors, and eliminate the need for an external power supply.
Extended DPM includes rate and total simultaneously, dynamic up-down counting, arithmetic functions applicable to channels A & B (A+B, A-B, A/B, AxB, A/B-1), phase angle, power factor, duty cycle, batch control, custom curve linearization.
The Laureate Panel Meter is easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.
All signal conditioner board ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated panel meter. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.
- An unfiltered selection provides true peak and valley readings and aids in control applications.
- A batch average filter selection averages each 16 conversions.
- An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.
Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.
Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.
An (isolated) 5, 10, 12, or 24 Vdc excitation output is standard to power transducers or two-wire transmitters. Ratiometric operation, which automatically compensates for changes in the applied excitation, is jumper selectable for applications, such as bridges, where the signal to be measured is proportional to the excitation level.
Display | |
---|---|
Readout | 5 LED digits, 7-segment, 14.2 mm (.56"), red or green. |
Range | -999,999 to +999,999 |
Indicators | Four LED lamps |
Inputs | |
Types | AC, pulses from NPN, PNP transistors, contact closures, magnetic pickups. |
Grounding | Common ground for channels A & B |
Minimum Signal | Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V). |
Maximum Signal | 250 Vac |
Noise Filter | 1 MHz, 30 kHz, 250 Hz (selectable) |
Contact Debounce | 0, 3, 50 ms (selectable) |
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. | |
Stopwatch Mode | |
Timing Modes: | |
With Ch A only | + to + edge, or - to - edge. |
With Ch A tied to Ch B | + to - edge, or - to + edge. |
With Ch A and Ch B | + edge of A to + edge of B, + edge of A to - edge of B, |
- edge to A to - edge of B, - edge of A to - edge of B | |
Timing Interval | 1 µs to 999,999 hrs |
Timing Resolution | 0.2 µs to 1 hr |
Selectable Decimal Time | 999999 H, M or S format with decimal point |
Selectable Clock Time | HH.MM.SS format |
Output & Display Update | 0 ms + programmable from 10 ms to 199.99 s |
Accuracy | |
Time Base | Crystal calibrated to ±2 ppm |
Span Tempco | ±1 ppm/°C (typ) |
Long-term Drift | ±5 ppm/year |
Power Supply Boards (one required) | |
Voltage, standard | 85-264 Vac or 90-300 Vdc |
Voltage, optional | 12-32 Vac or 10-48 Vdc |
Frequency | DC or 47-63 Hz |
Power Isolation | 250V rms working, 2.3 kV rms per 1 min test |
Excitation Output (standard) | |
5 Vdc | 5 Vdc ± 5%, 100 mA (jumper selectable) |
10 Vdc | 10 Vdc ± 5%, 120 mA (jumper selectable) |
12 Vdc | 12 Vdc ± 5%, 100 mA (jumper selectable) |
24 Vdc | 24 Vdc ± 5%, 50 mA (jumper selectable) |
Output Isolation | 50 Vdc from signal ground |
Analog Output Boards (one optional) | |
Output levels | 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (single-output option) |
4-20 mA, 0-20 mA, 0-10V (dual-output option) | |
Current compliance | 2 mA at 10V ( > 5 kΩ load) |
Voltage compliance | 12V at 20 mA (< 600 Ω load) |
Scaling | Zero and full scale adjustable from -99999 to +99999 |
Resolution | 16 bits (0.0015% of full scale) |
Isolation | 250V rms working, 2.3 kV rms per 1 min test |
(dual analog outputs share the same ground) | |
Relay Output Boards (one optional) | |
Dual magnetic relays | 2 Form C, 10A max, 440Vac or 125Vdc max, 2500VA or 300W |
Quad magnetic relays | 4 Form A (NO), 10A max, 440Vac or 125Vdc max, 2500VA or 300W |
Dual solid state relays | 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
Quad solid state relays | 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
Relay commons | Isolated commons for dual relays or each pair of quad relays |
Relay isolation | 250V rms working, 2.3 kV rms per 1 minute test |
Relay latching modes | Latching or non-latching |
Relay active modes | Active on or off, active high or low |
Hysteresis modes | QA passband mode, split hysteresis, span hysteresis |
Communication Boards (one optional) | |
Board selections | RS232, RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, Ethernet, USB-to-RS485 gateway, Ethernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485 |
Protocols | Modbus RTU, Modbus ASCII, Modbus TCP (Ethernet), Laurel ASCII |
Data rates | 300 to 19200 baud |
Isolation | 250V rms working, 2.3 kV rms per 1 min test |
Environmental | |
Operating temperature | -40°C to 70°C (-40°F to 158°F) |
Storage temperature. | -40°C to 85°C (-40°F to 185°F) |
Relative humidity | 95% at 40°C, non-condensing |
Protection | NEMA-4X (IP-65) when panel mounted |
Electrical Connections | |
![]() |
|
Mechanical | |
Enclosure | 1/8 DIN, high impact plastic, UL 94V-0, color: black |
Mounting | 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). |
Dimensions | 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D) |
Maximum panel thickness | 4.5 mm (0.18") |
Tightening Torque - Connectors | Screw terminal connectors: 5 lb-in (0.56 Nm) |
Tightening Torque - Pawls | Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm) |
Weight of base meter | 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display) |
Weight of option boards | 30 g (1.0 oz) typical per board (analog output, relay output, communications) |
General | |
Programming Methods | Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. |
Security | Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper. |
Warranty | 3 years parts & labor |
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. |
Free Instrument Setup Software for Series 2 Laureates
Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.
- When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
- When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.
Download Free Instrument Setup Software
Installation
Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:
- Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
- Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
- Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
- Reboot your computer for the changed UAC setting to take effect.

RJ11-to-DB9 cable with rear view of DB9 connector to PC

RS232 cable, meter to PC, P/N CBL01
Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.
Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.
Meter Setup Screens
Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.











Meter Setup Utilities




From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: List, Plot and Graph.
- List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.
- Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
- Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.


Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays

Key Features
- Meets 1/8 DIN Standard.
- Installs from front of panel.
- Short depth behind the panel: only 4" (102 mm) plus connectors.
- Understated 0.157" (4 mm) thick bezel.
- Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
- Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
- Rugged GE Lexan® housing material.
- Safety certified per EN 61010-1.
Dimensions

Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter: 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).
Panel Mounting
Slide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel.
The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.
Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.
Stopwatch Mode | |
---|---|
![]() |
The stopwatch mode is used to time single events to one microsecond resolution between start and stop pulses on the same channel. The width of a single waveshape can be measured by tying the A and B channels together. |
Timing Process Dynamics | |
![]() |
The start and stop pulses used for timing can be generated by the dual relay board in a Laureate analog panel meter or digital counter. For instance, the start and stop pulse edges can be created as temperature passes two alarm setpoints, or as temperature cycles in a hysteresis control mode. |
Rate Based on 1 / Time | |
![]() |
The Extended stopwatch meter can be programmed to display highly accurate rate or speed based on time. For example photodetectors on Channels A and B can provide timing pulses as a fast-moving object breaks two light beams, and the meter can then display speed in engineering units such as ft/sec or m/sec. The display will be held until reset by an external control input. |
Replacing an Oscilloscope with a Laureate Meter | |
![]() |
An oscilloscope is great for viewing and timing pulses in a lab. However, in fixed installations where digital timing accuracy and control outputs are required, a low-cost Laureate time interval meter will be the instrument of choice. Resolution to 0.2 µs is feasible. |
Instrumenting a Pulsed Laser System | |
![]() |
|
Some of the many possibilities in instrumenting a pulsed laser system with Laureate dual-channel counters: elapsed time, number of pulses, pulse width, pulse separation, duty cycle, and pulse rep rate. |
IPC
Splashproof Cover
CBL01
RS232 Cable for Meters
CBL02
USB-to-RS232 Adapter Cable
CBL04
RS232 Cable for LT Transmitters
CBL05
USB Data Cable for Meters
CBL06
USB-to-RS485 Adapter Cable
CBL07
USB Programming & Data Cable
CBL08
RS485 Splitter Cable
BKBD
RS485 RJ11 Terminal Block Adapter
Modular Design for Maximum Flexibility at Minimum Cost
All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boards, dual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.
The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Panel Meter.
Modular Hardware
The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for a panel meter or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.

Connecting Laureate Panel Meter to a Local Area Network (LAN)
Up to 30 Laureate Panel Meter and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.
Flexible Communication Options for Panel Meter
The Laureate Panel Meter can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.
Understanding the 1/8 DIN Panel Meter for a 6-Digit Digital Stopwatch and Timer
Introduction
In industrial, laboratory, and commercial environments, precise timing is essential for ensuring operational efficiency, maintaining quality control, and upholding safety standards. A 1/8 DIN Panel Meter integrated with a 6-digit digital stopwatch and timer provides a high-precision, compact solution for accurate time-based measurements. This advanced device combines the reliability of a standardized panel meter with the versatility of a high-resolution timing instrument, making it a critical tool for applications requiring meticulous time tracking. This section delves into the functionality, features, benefits, and extensive applications of this specialized Panel Meter.
What is a 1/8 DIN Panel Meter?
A 1/8 DIN Panel Meter is a compact electronic instrument designed to display numerical data in a wide range of settings, including manufacturing plants, research laboratories, and process control systems. The "1/8 DIN" designation refers to its standardized size, defined by the Deutsches Institut für Normung (DIN), with front panel dimensions of approximately 96mm x 48mm (3.78" x 1.89"). This compact footprint allows for seamless integration into control panels, dashboards, or instrumentation setups, even in space-constrained environments.
The Panel Meter is capable of processing and displaying various types of input signals, such as voltage, current, temperature, or time, using a digital LED or LCD display. In the case of a stopwatch and timer, the Panel Meter serves as a precise timing interface, providing clear, high-resolution readouts that enhance operational monitoring and control across diverse applications.
What is a 6-Digit Digital Stopwatch and Timer?
A 6-digit digital stopwatch and timer is a high-precision timing instrument designed to measure and display time intervals with exceptional detail. The six-digit display enables fine-grained time representation, typically covering hours, minutes, seconds, and fractions of a second (e.g., milliseconds or hundredths of a second). This level of resolution is ideal for applications requiring exact timing, such as monitoring production cycles, tracking experimental durations, or synchronizing automated processes.
The stopwatch function measures elapsed time from a starting point, while the timer function can count up to a target value or count down from a preset value, offering flexibility for a wide range of timing requirements. This dual functionality makes the Panel Meter adaptable to both continuous and event-based timing needs in industrial, scientific, and commercial settings.
How Does a 1/8 DIN Panel Meter with Stopwatch and Timer Work?
The integration of a 1/8 DIN Panel Meter with a 6-digit digital stopwatch and timer creates a powerful and user-friendly timing solution. The Panel Meter serves as the primary interface for displaying and controlling time data, leveraging internal or external signals to achieve high accuracy. The operation involves the following key steps:
-
Time Signal Processing: The Panel Meter processes timing signals from an internal high-precision clock or external triggers, such as pushbuttons, sensors, or electrical switches, to initiate, pause, or reset the stopwatch or timer functions.
-
Digital Conversion: Time data is converted into a digital format and displayed on the 6-digit screen with high resolution, ensuring precise and readable outputs for operators or control systems.
-
Programmable Controls: Users can configure settings such as time units (e.g., hours, minutes, seconds, or milliseconds), count direction (up or down), preset values, and alarm thresholds, tailoring the Panel Meter to specific application requirements.
-
Output and Integration: The Panel Meter supports outputs like programmable alarms, relays, or communication interfaces (e.g., RS-485, Modbus RTU) to trigger actions at specific time intervals or integrate with broader control systems, such as PLCs or SCADA platforms.
Key Features and Benefits
The 1/8 DIN Panel Meter with a 6-digit digital stopwatch and timer offers a robust set of features that enhance its utility in time-critical applications:
-
Compact Design: The standardized 1/8 DIN size ensures easy installation in space-constrained control panels, maximizing efficiency without compromising functionality.
-
High Precision: The 6-digit display provides fine resolution, enabling accurate measurement of time intervals down to milliseconds, critical for precise timing applications.
-
Versatility: Supports a wide range of industries and applications, from manufacturing and automation to scientific research, accommodating diverse timing needs.
-
Ease of Use: Features an intuitive digital interface with clear displays and simple controls for starting, stopping, resetting, or configuring the stopwatch and timer, accessible to operators with varying levels of expertise.
-
Customization: Offers programmable options for display formats, time units, and operational modes, allowing users to tailor the Panel Meter to specific requirements.
-
Robust Construction: Designed for industrial environments, with rugged enclosures and high IP ratings (e.g., IP65) for protection against dust, moisture, and harsh conditions.
-
Integration Capabilities: Supports multiple output options, including analog, digital, and serial communication, for seamless integration with control systems or data logging platforms.
Technical Specifications
While specific features vary by model, a typical 1/8 DIN Panel Meter with a 6-digit digital stopwatch and timer includes the following specifications:
- Display: 6-digit LED or LCD display with customizable time units and decimal points.
- Timing Resolution: Capable of measuring time intervals down to milliseconds or hundredths of a second.
- Input Types: Supports external triggers (e.g., NPN, PNP, or dry contact inputs) and manual controls for start/stop/reset functions.
- Power Supply: Typically supports 12-24V DC or 85-265V AC, accommodating various industrial power systems.
- Communication Options: RS-232, RS-485, Modbus RTU, or analog outputs for integration with control systems.
- Environmental Rating: IP65 or higher for front-panel protection against dust and water.
Applications
The 1/8 DIN Panel Meter with a 6-digit digital stopwatch and timer is a versatile tool used in a wide range of applications requiring precise time tracking. Its high-resolution display and programmable functionality make it suitable for:
- Manufacturing Processes: Monitors production cycle durations to ensure consistency, optimize throughput, and maintain quality standards in assembly lines or machining operations.
- Testing and Quality Control: Tracks test durations for product performance evaluations, ensuring accurate and repeatable results in quality assurance processes.
- Automation Systems: Synchronizes time-based operations in automated processes, such as coordinating robotic movements or controlling batch processing cycles.
- Research Laboratories: Measures precise time intervals for experiments in fields like chemistry, physics, or biology, ensuring reliable data collection.
- Sports and Fitness Equipment: Tracks workout or training durations in fitness machines, providing accurate timing for user performance monitoring.
Where Is a 1/8 DIN Panel Meter for a 6-Digit Digital Stopwatch and Timer Used?
The 1/8 DIN Panel Meter with a 6-digit digital stopwatch and timer is a critical instrument in industries and settings where timing accuracy directly impacts efficiency, quality, and safety. Its compact design, high precision, and robust integration capabilities make it indispensable across a variety of applications. Below is a detailed exploration of its primary use cases:
1. Manufacturing and Production Lines
In manufacturing, precise timing is essential for maintaining consistent production rates and ensuring product quality. The Panel Meter is used to:
- Monitor Cycle Times: Tracks the duration of each production step, ensuring processes adhere to time targets and optimizing overall throughput.
- Control Machine Operations: Manages timed operations, such as activating or deactivating machinery at precise intervals, enhancing automation accuracy and efficiency.
- Quality Control: Times processes like curing, coating, or heat treatment to prevent under- or over-processing, ensuring products meet stringent quality standards.
- Shift Performance Tracking: Measures operational durations to analyze shift productivity and identify opportunities for process improvements.
2. Laboratory Testing and Calibration
In research and testing laboratories, accurate timing is vital for ensuring the reliability of experimental results and equipment performance. The Panel Meter supports:
- Experiment Duration Tracking: Records precise time intervals for chemical reactions, physical tests, or biological processes, ensuring consistent and reproducible results.
- Instrument Calibration: Times calibration cycles for other laboratory devices, ensuring they meet required timing specifications and performance standards.
- Environmental Testing: Monitors durations for stress tests, such as temperature or humidity exposure, to evaluate material or product durability.
3. Automation Systems
Automation systems in industries like manufacturing, pharmaceuticals, and food processing rely on precise timing to ensure synchronized operations. The Panel Meter is used to:
- Synchronize Processes: Coordinates timing across multiple system components, preventing delays or misalignments in automated production lines.
- Control Batch Processing: Manages batch durations for processes like mixing, filling, or packaging, ensuring consistent output and regulatory compliance.
- Sequence Control: Triggers sequential operations at precise intervals, enhancing the efficiency of complex automated workflows.
4. Energy Management and Utilities
In energy and utility systems, timing plays a critical role in optimizing resource use and ensuring operational efficiency. The Panel Meter is applied in:
- Load Duration Monitoring: Tracks the operational time of specific loads, such as pumps or HVAC systems, to optimize energy consumption and reduce costs.
- Timed Operations Control: Manages timed processes in utilities, such as water treatment dosing or gas distribution, ensuring efficiency and compliance with regulations.
- Maintenance Scheduling: Monitors equipment runtime to schedule preventive maintenance, minimizing downtime and extending asset lifespan.
5. Transportation and Logistics
In transportation and logistics, precise timing enhances efficiency in goods movement and vehicle management. The Panel Meter supports:
- Transit Time Monitoring: Records travel durations for vehicles or goods to ensure adherence to delivery schedules and optimize route planning.
- Timed Dispatch Control: Manages vehicle dispatch intervals to prevent congestion and improve logistics flow in warehouses or distribution centers.
- Conveyor Timing: Tracks timing for conveyor operations, ensuring synchronized material handling in automated sorting or packaging systems.
6. Healthcare and Medical Equipment
In healthcare, accurate timing is critical for patient safety and treatment efficacy. The Panel Meter is used in:
- Medical Procedure Timing: Controls durations for devices like infusion pumps or ventilators, ensuring precise medication delivery or therapy administration.
- Treatment Monitoring: Tracks treatment durations for procedures like dialysis or radiation therapy, maintaining safety and effectiveness.
- Equipment Calibration: Times calibration cycles for medical devices, ensuring they operate within specified parameters for patient care.
7. Food and Beverage Industry
In food and beverage processing, timing is essential for ensuring product quality and safety. The Panel Meter is applied in:
- Processing Time Control: Monitors durations for cooking, baking, or pasteurization to achieve consistent product quality and comply with food safety standards.
- Packaging Operations: Times filling or sealing processes to maintain efficiency and accuracy in high-speed packaging lines.
- Fermentation Monitoring: Tracks fermentation durations to ensure optimal flavor and quality in products like beer, yogurt, or cheese.
Conclusion
The 1/8 DIN Panel Meter integrated with a 6-digit digital stopwatch and timer is a versatile, high-precision tool that plays a pivotal role in time-critical applications across multiple industries. Its compact design, high-resolution display, and robust integration capabilities make it indispensable for ensuring operational efficiency, quality control, and safety in manufacturing, laboratories, automation, energy management, transportation, healthcare, and food processing. As industries continue to advance and demand greater precision, the role of this Panel Meter will remain central to achieving reliable and accurate timing in complex processes.
Less Information.