Features
- Five jumper-selectable resistance ranges of 20.000 ohm to 200.00 kohm
- Three fixed factory-special ranges of 2.0000 ohm, 2.0000 Mohm, 20.000 Mohm
- Accuracy at 25°C ±0.01% of reading ± 2 counts
- 0.1 milliohm resolution on 2 ohm scale for contact resistance measurements
- 2, 3 or 4-wire connection with lead resistance compensation
- All input ranges are user selectable and factory calibrated
- Up to 60 conversions per second, Ideal for peak or valley capture
- Digital span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999
- Front panel scalable to ±99,999 for use with current shunts
- 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
- Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
- Operating temperature from -40°C to 70°C (-40°F to 158°F)
- Wide choice of Plug-in-Play options:
- 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
- 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
- Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)
- Extended DPM allows up to 180 data points to linearize and scale
nonlinear resistance sources
The Laureate™ 1/8 DIN Panel Meters, Ohmmeter for resistance in Ohms
is ideal for high-speed, high-accuracy resistance measurements in a production environment, such as contact resistance measurements. It is factory calibrated for five jumper selectable resistance ranges from 20.000 ohm to 200.00 kohm. Fixed, factory-special ranges of 2.0000 ohm, 2.0000 Mohm and 20.000 Mohm are also available. Accuracy is an exceptional ±0.01% of reading ± 2 counts. Resolution is one part in 20,000. In the 2 ohm range, resolution is 0.1 milliohm, making the panel meters suitable for contact resistance measurements.The optional extended Laureate computer board enhances Laureate Panel Meters by displaying rates derived from successive readings and enabling highly accurate custom curve linearization. For example, it can calculate liquid volume or flow rate in a horizontal cylindrical tank using levels from a 4-20 mA transmitter. Setup is straightforward: users input up to 180 data points into a spreadsheet or text file, and the computer calculates spline-fit segments, which are then downloaded to the panel meters for precise operation.
Panel meters connections can be via 2, 3 or 4 wires. With 4-wire hookup, 2 wires are used for excitation and two separate wires are used to sense the voltage across the resistance to be measured, thereby eliminating any lead resistance effects. With 3-wire hookup, the panel meters sense the combined voltage drop across the resistance to be measured plus two excitation leads. It also senses the voltage drop across one excitation lead, and then subtracts twice this voltage from the combined total. This technique effectively subtracts lead resistance if the excitation leads are the same.
All resistance ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated panel meters. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.
Laureate Panel Meters are easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.
High read rate of up to 50 or 60 conversions per second, the Laureate™ Panel Meters use Concurrent Slope (US Pat. 5,262,780) analog-to-digital conversion to integrate signals over a full power line cycle (50 Hz or 60 Hz). This read rate enables peak and valley capture, real-time computer interfacing, and control applications. Peak and valley values are automatically captured and can be viewed using Laurel’s free Instrument Setup Software (compatible with Windows PCs) or transmitted as serial data.
- An unfiltered selection provides true peak and valley readings and aids in control applications.
- A batch average filter selection averages each 16 conversions.
- An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.
Two tare functions: auto-tare and manual tare. In auto-tare, an input line is grounded by an external pushbutton. This causes the current weight, which is normally the empty weight of the container to be stored in memory as an offset. In manual tare, the tare value can be entered manually via the front panel or a computer using Laurel's free Instrument Setup Software. For instance, the tare value may be the stated empty weight of a truck or rail car. Pressing the Reset button on the front panel toggles the display between gross weight (total weight on the scale) and net weight (gross weight with tare subtracted).
Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.
Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.
Resistance Measurement with Excitation & Lead Compensation
Ohmmeter hookup can be via 2, 3 or 4 wires to the J5 connector. The panel meters apply a fixed excitation current for each resistance range. | |
![]() |
In 4-wire hookup, different pairs of leads are used to apply the excitation current and sense the voltage drop across the unknown resistance, so that the IR drop across the excitation leads is not a factor. |
![]() |
In 3-wire hookup, the panel meters sense the combined voltage drop across the unknown resistance plus two excitation leads. It also senses the voltage drop across one excitation lead, and then subtracts twice this voltage from the combined total. This technique effectively subtracts all lead resistance and compensates for ambient temperature changes if the two excitation leads are identical. |
![]() |
In 2-wire hookup, the panel meters sense the combined voltage drop across the unknown resistance and both lead wires. The voltage drop across the lead wires can be measured by shorting out the resistance during meter setup, and this voltage is then automatically subtracted from the combined total. However, changing resistance of the lead wires due to ambient temperature changes will not be compensated. |
QA Application with Relay Option in Passband Mode
![]() |
A deviation limit (50 mohm in this example) is set up around both sides of a setpoint. The relay closes (or opens) when the reading falls within the deviation band, and opens (or closes) when the reading falls outside of this band. This mode sets up a passband around the setpoint and can be used for contact resistance testing.
|
Range | Ohms | Resolution | Accuracy | Excitation Current *** |
---|---|---|---|---|
R0** | 0-2.0000 Ω | 0.1 mΩ | ±0.01% of reading ± 2 counts |
5 mA |
R1* | 0-20.000 Ω | 1 mΩ | 5 mA | |
R2* | 0-200.00 Ω | 10 mΩ | 500 µA | |
R3* | 0-2000.0 Ω | 100 mΩ | 50 µA | |
R4* | 0-20000 Ω | 1 Ω | 5 µA | |
R5* | 0-200.00 kΩ | 10 Ω | 500 nA | |
R6** | 0-2.0000 MΩ | 100 Ω | 500 nA | |
R7** | 0-20.0000 MΩ | 1000 Ω | 80 nA | |
* Jumper-selectable, precalibrated range. | ||||
** Factory-set fixed range. | ||||
*** The applied excitation current is sensed by the meter, which operates in a ratiometric mode and automatically compensates for any changes in excitation. | ||||
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. |
Display | |
---|---|
Readout | 5 LED digits, 7-segment, 14.2 mm (.56") |
Color | Red or green LED |
Indicators | 2 red LED lamps |
Accuracy | |
Accuracy at 25°C | ±0.01% of reading ± 2 counts |
Span tempco | ±0.003% of reading/°C |
Electrical | |
Connection | 2, 3 or 4-wire |
Max applied voltage | 100 mV |
Overvoltage protection | 125 Vac |
Open sensor indication | Flashes full-scale |
A-to-D Conversion | |
Technique | Concurrent Slope (Pat 5,262,780) |
A-to-D rate | 60/s at 60 Hz, 50/s at 50 Hz |
Output update rate | 56/s at 60 Hz, 47/s at 50 Hz |
Display update rate | 3.5/s at 60 Hz, 3/s at 50 Hz |
Power Supply Boards (one required) | |
Voltage, standard | 85-264 Vac or 90-300 Vdc |
Voltage, optional | 12-32 Vac or 10-48 Vdc |
Frequency | DC or 47-63 Hz |
Power consumption (typical, base meter) | 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc, 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc |
Power Isolation | 250V rms working, 2.3 kV rms per 1 min test |
Analog Output Board (one optional) | |
Output levels | 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (jumper selectable) |
Current compliance | 2 mA at 10V ( > 5 kΩ load) |
Voltage compliance | 12V at 20 mA (< 600 Ω load) |
Scaling | Zero and full scale adjustable from -99999 to +99999 |
Resolution | 16 bits (0.0015% of full scale) |
Step function response | 80 ms to 99% of final value (typ) |
Isolation | 250V rms working, 2.3 kV rms per 1 min test |
Relay Output Boards (one optional) | |
Dual magnetic relays | 2 Form C, 10A max, 440Vac or 125Vdc max, 2500VA or 300W |
Quad magnetic relays | 4 Form A (NO), 10A max, 440Vac or 125Vdc max, 2500VA or 300W |
Dual solid state relays | 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
Quad solid state relays | 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
Relay commons | Isolated commons for dual relays or each pair of quad relays |
Relay isolation | 250V rms working, 2.3 kV rms per 1 minute test |
Step function response | 30 ms (typ) for contact relays, 25 ms (typ) for solid state relays |
Relay latching modes | Latching or non-latching |
Relay active modes | Active on or off, active high or low |
Hysteresis modes | QA passband mode, split hysteresis, span hysteresis |
Communication Boards (one optional) | |
Board selections | RS232, RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, Ethernet, USB-to-RS485 gateway, Ethernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485 |
Protocols | Laurel Custom ASCII (serial), Modbus RTU (serial), Modbus TCP (Ethernet or WiFi) |
Digital addresses | 247 (Modbus), 31 (Laurel ASCII), |
Isolation | 250V rms working, 2.3 kV rms per 1 min test |
Environmental | |
Operating temperature | -40°C to 70°C (-40°F to 158°F) |
Storage temperature. | -40°C to 85°C (-40°F to 185°F) |
Relative humidity | 95% at 40°C, non-condensing |
Protection | NEMA-4X (IP-65) when panel mounted |
Mechanical | |
Enclosure | 1/8 DIN, high impact plastic, UL 94V-0, color: black |
Mounting | 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). |
Dimensions | 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D) |
Maximum panel thickness | 4.5 mm (0.18") |
Tightening Torque - Connectors | Screw terminal connectors: 5 lb-in (0.56 Nm) |
Tightening Torque - Pawls | Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm) |
Weight of base meter | 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display) |
Weight of option boards | 30 g (1.0 oz) typical per board (analog output, relay output, communications) |
General | |
Programming Methods | Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. |
Security | Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper. |
Warranty | 3 years parts & labor |
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. |
Free Instrument Setup Software for Series 2 Laureates
Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.
- When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
- When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.
Download Free Instrument Setup Software
Installation
Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:
- Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
- Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
- Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
- Reboot your computer for the changed UAC setting to take effect.

RJ11-to-DB9 cable with rear view of DB9 connector to PC

RS232 cable, meter to PC, P/N CBL01
Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.
Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.
Meter Setup Screens
Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.











Meter Setup Utilities




From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: List, Plot and Graph.
- List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.
- Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
- Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.


Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays

Key Features
- Meets 1/8 DIN Standard.
- Installs from front of panel.
- Short depth behind the panel: only 4" (102 mm) plus connectors.
- Understated 0.157" (4 mm) thick bezel.
- Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
- Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
- Rugged GE Lexan® housing material.
- Safety certified per EN 61010-1.
Dimensions

Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter: 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).
Panel Mounting
Slide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel.
The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.
Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.
IPC
Splashproof Cover
CBL01
RS232 Cable for Meters
CBL02
USB-to-RS232 Adapter Cable
CBL04
RS232 Cable for LT Transmitters
CBL05
USB Data Cable for Meters
CBL06
USB-to-RS485 Adapter Cable
CBL07
USB Programming & Data Cable
CBL08
RS485 Splitter Cable
BKBD
RS485 RJ11 Terminal Block Adapter
Modular Design for Maximum Flexibility at Minimum Cost
All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boards, dual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.
The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Panel Meters.
Modular Hardware
The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for panel meters or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.

Connecting Laureate Panel Meters to a Local Area Network (LAN)
Up to 30 Laureate Panel Meters and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.
Flexible Communication Options for Panel Meters
Laureate Panel Meters can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.
What are 1/8 DIN Panel Meters Ohmmeters for Resistance in Ohms?
1/8 DIN Panel Meters ohmmeters are specialized instruments designed to measure electrical resistance, expressed in ohms (Ω), with high precision. These Panel Meters are critical in industrial, laboratory, and commercial settings where accurate resistance measurements are essential for system performance, quality control, and safety. The "1/8 DIN" specification refers to their standardized physical dimensions, ensuring compatibility with standard industrial panel cutouts. This section explores the functionality, features, technical specifications, and applications of these Panel Meters, highlighting their importance in various industries.
Key Features of 1/8 DIN Panel Meters Ohmmeters
-
Compact Size
The 1/8 DIN format corresponds to Panel Meters measuring approximately 96mm by 48mm (3.78 x 1.89 inches). This compact size optimizes space in control panels, making these Panel Meters ideal for applications where panel real estate is limited. -
Digital Display
These Panel Meters feature clear, high-contrast digital displays, typically LED or LCD, providing precise and easy-to-read resistance measurements. Adjustable brightness ensures visibility in various lighting conditions. -
Resistance Measurement (Ohmmeter Functionality)
The primary function of these Panel Meters is to measure electrical resistance, a critical parameter in electrical and electronic applications. Accurate resistance measurements ensure proper system operation and facilitate troubleshooting. -
High Accuracy
Designed for precision, these Panel Meters offer measurements down to milliohms or micro-ohms, depending on the model. This high accuracy is essential for applications like quality control, component testing, and research. -
Ease of Integration
These Panel Meters are engineered for seamless installation into control systems, featuring simple wiring connections and support for features like alarms, analog outputs, or communication interfaces for enhanced functionality. -
Versatility
While primarily designed for resistance measurement, many 1/8 DIN Panel Meters are multifunctional, capable of measuring additional parameters like voltage, current, or temperature, making them adaptable to various industrial needs.
Technical Specifications
Typical specifications for 1/8 DIN Panel Meters ohmmeters include:
- Measurement Range: Micro-ohms to mega-ohms, depending on the model.
- Accuracy: ±0.1% of full scale or better.
- Display: 4-6 digit LED or LCD with customizable brightness and decimal points.
- Power Supply: 12-24V DC or 85-265V AC.
- Communication: RS-232, RS-485, Modbus RTU, or Ethernet.
- Environmental Rating: IP65 or higher for front panel protection.
- Operating Temperature: -10°C to 50°C, suitable for industrial environments.
Applications of 1/8 DIN Panel Meters Ohmmeters
-
Industrial Control Panels
These Panel Meters are integrated into industrial control panels to monitor the resistance of circuits, components, or materials in real-time, ensuring processes operate within specified parameters and preventing equipment failures. -
Testing and Calibration
In laboratories or production environments, these Panel Meters are used for precise testing and calibration of components like resistors, coils, or cables, ensuring compliance with design specifications. -
Electrical Maintenance
Maintenance professionals use these Panel Meters to check the resistance of circuits and components, identifying issues like loose connections, corrosion, or faulty parts to prevent system failures. -
Quality Control
In manufacturing, these Panel Meters ensure consistent resistance measurements for components, critical for maintaining quality standards in industries like electronics and automotive.
Conclusion
1/8 DIN Panel Meters ohmmeters are compact, accurate, and versatile instruments designed for precise measurement of electrical resistance in ohms. Their standardized size, high-precision digital displays, and robust integration capabilities make them essential in industrial, laboratory, and maintenance settings. By ensuring reliable resistance measurements, these Panel Meters contribute to system performance, safety, and quality across various applications.
Where are 1/8 DIN Panel Meters Ohmmeters for Resistance in Ohms Used?
1/8 DIN Panel Meters ohmmeters are specialized devices designed to measure resistance in ohms with high accuracy, used in a wide range of industrial, laboratory, and commercial applications. Their compact size, precision, and ease of integration make them essential for monitoring and controlling electrical resistance in various environments. Below are the primary industries and applications where these Panel Meters are deployed.
-
Industrial Process Control
In industrial settings, these Panel Meters monitor the resistance of components like heating elements, sensors, or wiring, ensuring optimal operation and preventing failures due to resistance variations. They are commonly integrated into control panels for real-time monitoring. -
Quality Control and Testing
Manufacturers use these Panel Meters in quality control to verify the resistance of components like resistors, coils, or connectors, ensuring they meet industry standards. They are integrated into test rigs or workstations for efficient and accurate testing. -
Laboratory Research
In research laboratories, these Panel Meters provide precise resistance measurements for experiments in materials science, physics, or electronics, supporting accurate data collection in compact lab setups. -
Power Distribution Systems
In power distribution, these Panel Meters monitor the resistance of cables, transformers, or connectors in substations or control rooms, detecting issues like corrosion or insulation degradation to maintain network reliability. -
HVAC Systems
In HVAC systems, these Panel Meters measure the resistance of thermistors or heating elements, ensuring efficient and safe operation by monitoring system health and performance. -
Automotive Industry
In automotive production and diagnostics, these Panel Meters measure the resistance of sensors, wiring, or electrical components, ensuring vehicles meet safety and performance standards. -
Renewable Energy Systems
In solar power or wind turbine systems, these Panel Meters monitor the resistance of components like inverters or battery connections, optimizing performance and ensuring system reliability.
Conclusion
1/8 DIN Panel Meters ohmmeters for resistance measurement are versatile and reliable tools used across industries like industrial process control, quality assurance, laboratory research, power distribution, HVAC, automotive, and renewable energy. Their compact size, high accuracy, and robust integration capabilities make them essential for ensuring performance and safety in electrical systems. By providing precise, real-time resistance data, these Panel Meters contribute significantly to operational efficiency, quality control, and system reliability.
Less Information.