Features
- Two independently scalable totals for Channels A & B
- Inputs from NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC inputs up to 250 Vac
- Two independently field-scalable pulse input channels from 0.005 Hz to 1 MHz
- Up counting from zero to preset value using positive scale factor
- Down counting from preset to zero using negative scale factor
- Totals stored in non-volatile memory
- Digital span adjust from 0 to ±999,999, zero adjust from -999,999 to +999,999
- Front panel scalable: to ±999,999 for use with current shunts
- 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
- Transducer excitation output, 5, 10, 12, or 24 Vdc (isolated)
- Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
- Operating temperature from -40°C to 70°C (-40°F to 158°F)
- Wide choice of Plug-in-Play options:
- 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
- 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
- Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)
- Extended DPM version - See below for all capabilities
Certificates of Compliance
The Laureate 1/8 DIN Panel Meters for dual-channel up or down totalizer
is a Standard operating mode of the Laureate counter with the FR dual-channel signal conditioner board that can display frequencies from 0.005 Hz to 1 MHz. Each channel (A or B) may be independently set up and scaled to count up from zero (or other value) to a preset limit, or to count down from a preset value to zero (or other limit). Countdown operation is set up by entering a negative scale factor.The six-digit counter display is capable of displaying any value from -999,999 to 999,999 with a programmable decimal point. Scaling allows direct readout in engineering units, such as gallons or cubic feet based on counts from a turbine flowmeter, or the count of cans based on the count of six-packs. The displayed channel (A or B) is selected via a front panel pushbutton. The totals are stored in non-volatile memory so as to be retained in the absence of power.
The minimum recommended complementary option for the Laureate totalizer is the dual setpoint controller output board, which is available with either 8A relays or AC/DC solid state relays.
Laureate Panel Meters are easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.
All signal conditioner board ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated panel meters. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.
An Optional Extended DPM Provides Capabilities Beyond Those of the Standard Counter:
- Rate and total simultaneously. Channel A can display total while Channel B displays rate. The selection of A or B for display is via a front panel pushbutton. This mode is ideal for flow applications.
- Up/down counting. Channel A can serve as an up/down counter, where the count direction is dynamically changed by applying a signal to Channel B. For instance, Channel A can count and scale pulses from a turbine flow meter, while Channel B inputs the direction of flow. This allows total volume to be tracked in case of reversible flow.
- Totalizing with external inhibit. Totalizing by Channel A can be temporarily inhibited by applying a signal to Channel B. For instance, 60 Hz AC pulses can be counted by Channel A and be scaled to display elapsed hours. A signal can be applied to Channel B to start or stop pulse counting when a process is in operation.
- Custom curve linearization. Exceptionally accurate custom curve linearization is achievable, for example to linearize the low end of turbine flow meters. For setup, up to 180 data points can be input into a spreadsheet or text file by the user. The computer then calculates spline fit segments, which are downloaded into the panel meters via RS232. The linearized rate can then be totalized by the Extended counter.
- Arithmetic functions. The Extended counter makes arithmetic functions available, namely A+B, A-B, AxB, A/B and A/B-1. These solve many applications. For instance, A+B allows two input flows to be summed for total volume, while A-B allows outflow to be subtracted from inflow for net volume. A/B allows the mixing of ingredients in a specified ratio. By monitoring and alarming the A/B volume ratio, ingredient B can be added to A until the proper ratio is achieved.
The FR dual-channel signal conditioner accepts inputs from proximity switches with a PNP or NPN output, TTL or CMOS logic, magnetic pickups, contact closures, low-level outputs from turbine flow meters down to 12 mV, and high-level AC line inputs up to 250 Vac. Jumper selections provide optimum operation for different sensor types and noise conditions. A built-in (isolated) 5, 10, 12, or 24 Vdc excitation supply can power proximity switches and other sensors, and eliminate the need for an external power supply.
- An unfiltered selection provides true peak and valley readings and aids in control applications.
- A batch average filter selection averages each 16 conversions.
- An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.
Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.
Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.
An (isolated) 5, 10, 12, or 24 Vdc excitation output is standard to power transducers or two-wire transmitters. Ratiometric operation, which automatically compensates for changes in the applied excitation, is jumper selectable for applications, such as bridges, where the signal to be measured is proportional to the excitation level.
| Display | |
|---|---|
| Readout | 6 LED digits, 7-segment, 14.2 mm (.56"), red or green. |
| Color | Red or green LED |
| Display Range | -999,999 to +999,999, XXXXEX notation beyond 999,999 |
| Zero Adjust | -999,999 to +999,999 |
| Span Adjust | 0 to ±999,999 |
| Indicators | Four LED lamps |
| Inputs | |
| Types | AC, pulses from NPN, PNP transistors, contact closures, magnetic pickups. |
| Signal Ground | Common ground for channels A & B |
| Channel A Freq. | 0 Hz to 1 MHz |
| Channel B Freq. | 0 Hz to 250 kHz |
| Minimum Signal | Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V). |
| Maximum Signal | 250 Vac |
| Noise Filter | 1 MHz, 30 kHz, 250 Hz (selectable) |
| Contact Debounce | 0, 3, 50 ms (selectable) |
| Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. | |
| Excitation Output (standard) | |
| 5 Vdc | 5 Vdc ± 5%, 100 mA (jumper selectable) |
| 10 Vdc | 10 Vdc ± 5%, 120 mA (jumper selectable) |
| 12 Vdc | 12 Vdc ± 5%, 100 mA (jumper selectable) |
| 24 Vdc | 24 Vdc ± 5%, 50 mA (jumper selectable) |
| Output Isolation | 50 Vdc from signal ground |
| Power Supply Boards (one required) | |
| Voltage, standard | 85-264 Vac or 90-300 Vdc |
| Voltage, optional | 12-32 Vac or 10-48 Vdc |
| Frequency | DC or 47-63 Hz |
| Power consumption (typical, base meter) | 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc, 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc |
| Power Isolation | 250V rms working, 2.3 kV rms per 1 min test |
| Analog Output Boards (one optional) | |
| Output levels | 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (single-output option) |
| 4-20 mA, 0-20 mA, 0-10V (dual-output option) | |
| Current compliance | 2 mA at 10V ( > 5 kΩ load) |
| Voltage compliance | 12V at 20 mA (< 600 Ω load) |
| Scaling | Zero and full scale adjustable from -99999 to +99999 |
| Resolution | 16 bits (0.0015% of full scale) |
| Isolation | 250V rms working, 2.3 kV rms per 1 min test |
| (dual analog outputs share the same ground) | |
| Relay Output Boards (one optional) | |
| Dual magnetic relays | 2 Form C, 10A max, 440Vac or 125Vdc max, 2500VA or 300W |
| Quad magnetic relays | 4 Form A (NO), 10A max, 440Vac or 125Vdc max, 2500VA or 300W |
| Dual solid state relays | 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
| Quad solid state relays | 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
| Relay commons | Isolated commons for dual relays or each pair of quad relays |
| Relay isolation | 250V rms working, 2.3 kV rms per 1 minute test |
| Relay latching modes | Latching or non-latching |
| Relay active modes | Active on or off, active high or low |
| Hysteresis modes | QA passband mode, split hysteresis, span hysteresis |
| Communication Boards (one optional) | |
| Board selections | RS232, RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, Ethernet, USB-to-RS485 gateway, Ethernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485 |
| Protocols | Laurel Custom ASCII (serial), Modbus RTU (serial), Modbus TCP (Ethernet or WiFi) |
| Digital addresses | 247 (Modbus), 31 (Laurel ASCII), |
| Isolation | 250V rms working, 2.3 kV rms per 1 min test |
| Environmental | |
| Operating temperature | -40°C to 70°C (-40°F to 158°F) |
| Storage temperature. | -40°C to 85°C (-40°F to 185°F) |
| Relative humidity | 95% at 40°C, non-condensing |
| Protection | NEMA-4X (IP-65) when panel mounted |
| Signal Connections | |
![]() |
|
| Mechanical | |
| Enclosure | 1/8 DIN, high impact plastic, UL 94V-0, color: black |
| Mounting | 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). |
| Dimensions | 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D) |
| Maximum panel thickness | 4.5 mm (0.18") |
| Tightening Torque - Connectors | Screw terminal connectors: 5 lb-in (0.56 Nm) |
| Tightening Torque - Pawls | Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm) |
| Weight of base meter | 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display) |
| Weight of option boards | 30 g (1.0 oz) typical per board (analog output, relay output, communications) |
| General | |
| Programming Methods | Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. |
| Security | Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper. |
| Warranty | 3 years parts & labor |
| Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. | |
Free Instrument Setup Software for Series 2 Laureates
Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.
- When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
- When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.
Download Free Instrument Setup Software
Installation
Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:
- Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
- Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
- Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
- Reboot your computer for the changed UAC setting to take effect.
RJ11-to-DB9 cable with rear view of DB9 connector to PC

RS232 cable, meter to PC, P/N CBL01
Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.
Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.
Meter Setup Screens
Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.
Meter Setup Utilities
From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: List, Plot and Graph.
- List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.
- Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
- Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.

Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays
Key Features
- Meets 1/8 DIN Standard.
- Installs from front of panel.
- Short depth behind the panel: only 4" (102 mm) plus connectors.
- Understated 0.157" (4 mm) thick bezel.
- Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
- Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
- Rugged GE Lexan® housing material.
- Safety certified per EN 61010-1.
Dimensions
Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter: 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).
Panel Mounting
Slide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel.
The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.
Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.
| Up/Down Totalizing | |
|---|---|
|
Up/down totalizing is provided by a mode of the Extended counter where pulses are either added or subtracted on Channel A based on a direction input on Channel B. The counter can also be programmed so that counting by Channel A is inhibited by an input on Channel B. |
| Combining Two Totals | |
![]() |
A+B, A-B and A/B arithmetic functions are available with the Extended counter. A+B sums both totals, while A-B subtracts the outflow total from inflow total. The A/B ratio applied to total helps assure the proper mixing of components. Controller setup and monitoring of the mixing operation are facilitated by optional serial communications. RS485 allows a single data line to handle multiple controllers. |
| Up or Down Counting with Preset | |
![]() |
A single Laureate dual-channel counter will handle two repetitive fill operations by counting from zero up to a preset, or down from a preset to zero. A dual setpoint relay board is required. |
| Machine Rune Time and Utilization | |
![]() |
An easy way to measure the run time of machines is to count AC line cycles and scale the total to hours. To display machine utilization or duty cycle in percent, use the Extended counter. Connect Channel A to switched AC and Channel B to the AC line, and have the counter display the A/B ratio with a 100 multiplier. |
| Total and Rate Simultaneously | |
![]() |
The Extended version of the Laureate dual channel counter can display scaled rate or total for the same channel at the push of a button, and alarm both the rate and total. The Extended version can also do curve linearization, thereby extending the working range and accuracy of flow transducers. |
| System-level Capabilities | |
| The Laureate dual channel totalizer can independently scale, display and alarm two totals, and the totals plus alarm data can be transmitted via RS232 or RS485. The displayed totals can also be transmitted as an isolated 4-20 mA or 0-10V analog output. The Extended version can further display and transmit arithmetic combinations of the two totals. | ![]() |
CAL-Digital
Certificate of Calibration
$65.00DLS-XLOG2
XLog2 Data logging Software
$495.00IPC
Splashproof Cover
$48.00CON01
CON01 Connector
$75.00CBL01
RS232 Cable for Meters
$35.00CBL02
USB-to-RS232 Adapter Cable
$47.00CBL04
RS232 Cable for LT Transmitters
$47.00CBL05
USB Data Cable for Meters
$47.00CBL06
USB-to-RS485 Adapter Cable
$47.00CBL07
USB Programming & Data Cable
$47.00CBL08
RS485 Splitter Cable
$33.00Modular Design for Maximum Flexibility at Minimum Cost
All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boards, dual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.
The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Panel Meters.
Modular Hardware
The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for panel meters or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.
Connecting Laureate Panel Meters to a Local Area Network (LAN)
Up to 30 Laureate Panel Meters and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.
Flexible Communication Options for Panel Meters
Laureate Panel Meters can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.

Understanding 1/8 DIN Panel Meters for Dual-Channel Pulse Input Totalizer
In industrial and process control environments where precision counting and accumulation of events are essential for efficiency, quality, and safety, 1/8 DIN Panel Meters for Dual-Channel Pulse Input Totalizer are compact, high-performance instruments designed to deliver accurate pulse counting and totalization from two independent channels. These Panel Meters are engineered to process high-speed pulse signals from sensors or devices, providing reliable totals, rates, and control outputs. Their standardized 1/8 DIN size and robust features make them ideal for applications ranging from production monitoring to flow totalization and inventory tracking. This overview explores their functionality, key features, technical advantages, and diverse applications across modern industrial settings.
What are 1/8 DIN Panel Meters?
1/8 DIN Panel Meters are compact electronic instruments designed to fit into a standard 1/8 DIN cutout, measuring approximately 96 x 48 mm (3.78 x 1.89 inches). The term "DIN" refers to the Deutsches Institut für Normung, the German Institute for Standardization, which defines standard sizes for instrumentation to ensure compatibility with control panels worldwide. This compact form factor allows 1/8 DIN Panel Meters to integrate easily into space-constrained environments while providing robust measurement and control capabilities.
These Panel Meters are engineered to process digital or pulse signals from sensors, such as proximity switches, optical encoders, flow meters, or counters, and convert them into clear digital readouts for real-time monitoring. With features like high-resolution displays, programmable functions, and advanced connectivity, 1/8 DIN Panel Meters are tailored for demanding totalization applications across industries ranging from manufacturing and food processing to logistics and energy management.
Role of 1/8 DIN Panel Meters in Dual-Channel Pulse Input Totalization
In totalization applications, accuracy, reliability, and ease of use are paramount. 1/8 DIN Panel Meters for Dual-Channel Pulse Input Totalizer are designed to interface seamlessly with pulse-output devices, such as turbine flow meters, positive displacement meters, or proximity sensors, to provide precise counting and accumulation from two independent channels. They are used in industries such as manufacturing, food processing, logistics, pharmaceuticals, and agriculture, where accurate event counting or volume totalization is critical for quality assurance, process control, inventory management, and regulatory compliance. By offering stable, repeatable totals with features like up/down counting and preset batch counts, these Panel Meters help prevent errors, reduce waste, and improve overall operational efficiency.
Key Functions of 1/8 DIN Panel Meters for Dual-Channel Pulse Input Totalizer
1/8 DIN Panel Meters perform several essential functions in totalization systems:
- Dual-Channel Pulse Acquisition
These Panel Meters receive pulse inputs from two separate channels, allowing simultaneous monitoring of independent sources, such as two flow meters or production counters. - High-Speed Counting and Totalization
Built-in counters support high-speed inputs (up to 1 MHz in many models), accumulating totals with scalable K-factors to convert pulses into meaningful units like liters, pieces, or meters. - Up/Down and Directional Counting
Advanced models include directional logic for up/down counting, ideal for bidirectional flow or position tracking applications. - Data Output and Connectivity
Many 1/8 DIN Panel Meters offer data output options, including serial communication (RS-232, RS-485, Modbus RTU) and analog outputs (4–20 mA or 0–10 V). This enables integration with PLCs, data loggers, remote displays, or SCADA systems for advanced processing, recording, or centralized control. - Alarms and Setpoints
Programmable alarms and setpoints trigger alerts or control actions when totals or rates reach thresholds, supporting automation, batch completion detection, and quality control in counting processes.
Advantages of Using 1/8 DIN Panel Meters for Dual-Channel Pulse Input Totalizer
Implementing 1/8 DIN Panel Meters in totalization applications offers numerous advantages:
- Compact Size and Space Efficiency
The 1/8 DIN form factor allows these Panel Meters to fit into crowded control panels or retrofits, optimizing space without requiring major modifications to existing equipment layouts. - Ease of Installation and Compatibility
Standardized dimensions and mounting mechanisms simplify installation, reducing downtime during setup or replacement in both new and legacy systems. - Versatility Across Applications
These Panel Meters are compatible with a wide range of pulse-output sensors, supporting diverse totalization tasks from industrial counting to laboratory dosing and portable systems. - Durability in Harsh Environments
Built with rugged enclosures and high IP ratings (e.g., IP65), 1/8 DIN Panel Meters withstand dust, moisture, vibration, and temperature extremes common in industrial settings. - High Precision and Repeatability
Advanced signal processing and high-speed counting ensure accurate totals with minimal variation, critical for maintaining quality and compliance in regulated industries.
Technical Specifications (Typical)
While specifications vary by model, typical features of 1/8 DIN Panel Meters for dual-channel pulse input totalizer include:
- Input Compatibility: Supports pulse inputs from flow meters, counters, or sensors with high-speed counting up to 1 MHz
- Accuracy: ±0.01% of full scale or better with K-factor scaling
- Display: 4-6 digit LED or LCD with customizable brightness and decimal points
- Power Supply: 12-24V DC or 85-265V AC
- Communication: RS-232, RS-485, Modbus RTU, or Ethernet for integration with control systems
- Outputs: Dual relays for batch sequencing, analog (4–20 mA or 0–10 V)
- Environmental Rating: IP65 or higher for front panel protection
Where Are 1/8 DIN Panel Meters for Dual-Channel Pulse Input Totalizer Used?
1/8 DIN Panel Meters for dual-channel pulse input totalizer are essential in various industries where precise event counting or volume totalization from two sources is a cornerstone of operational success. Their compact size, high accuracy, and robust integration capabilities make them ideal for totalization systems in diverse settings. Below is a detailed exploration of the primary industries and applications where these Panel Meters are deployed.
1. Industrial Manufacturing
In manufacturing environments, accurate event counting is crucial for quality control and process optimization. 1/8 DIN Panel Meters are integrated into totalization systems to display real-time data from pulse-output sensors. They are used in:
- Production Counting: Track parts or cycles from two lines to compare output, detect imbalances, or total combined production for efficiency reporting.
- Material Batching: Monitor dual inputs for ingredient dosing in mixing systems, ensuring precise formulation and reducing waste.
- Packaging Systems: Verify counts from two sensors to ensure accurate package quantities and compliance with specifications.
2. Chemical Processing
Chemical plants require precise measurement for product consistency and safety. 1/8 DIN Panel Meters are used to:
- Chemical Dosing: Totalize volumes from two flow sensors for accurate mixing ratios or net consumption tracking.
- Process Monitoring: Track batch quantities in real-time to maintain quality and detect deviations promptly.
- Safety Compliance: Use alarms to alert operators when totals deviate from setpoints, enhancing safety in volatile environments.
3. Water Treatment Facilities
In water treatment, accurate volume totalization is essential for compliance and efficiency. These Panel Meters are used to:
- Chemical Dosing: Totalize inputs from two meters for precise chemical addition based on flow rates.
- Flow Monitoring: Track total volumes processed for regulatory reporting and system optimization.
- Automation: Integrate with control systems to automate dosing processes, reducing manual intervention.
4. Food and Beverage Industry
The food and beverage industry relies on precision for quality and compliance. These Panel Meters are employed in:
- Portion Control: Ensure accurate quantities of ingredients in mixing or packaging processes to meet specifications.
- Ingredient Mixing: Monitor totals from two sources to maintain consistent batch sizes for products like sauces or beverages.
- Quality Assurance: Verify batch data to comply with food safety regulations and prevent defects.
5. Pharmaceutical Manufacturing
Pharmaceutical production demands exact measurements for drug safety and efficacy. These Panel Meters are used to:
- Ingredient Dosing: Totalize volumes from two sensors for precise addition of active ingredients or excipients.
- Batch Tracking: Record total quantities dispensed for quality assurance and regulatory compliance.
- Process Control: Use programmable setpoints to automate batch processes, ensuring consistency in volatile production conditions.
6. Petrochemical Industry
In the petrochemical industry, handling volatile materials requires precision. These Panel Meters are used to:
- Fuel Batching: Totalize volumes from two flow sensors for accurate dispensing of fuels or lubricants.
- Volume Monitoring: Track total volumes of processed chemicals for inventory and production management.
- Safety Systems: Trigger alarms for deviations in totals to prevent hazardous errors in high-risk environments.
7. Packaging Industry
The packaging industry requires precise control over product quantities. These Panel Meters are used to:
- Filling Machines: Totalize counts from two sensors for consistent package quantities in high-speed operations.
- Weight Verification: Ensure accurate totals to reduce waste and meet customer expectations.
- Automation Integration: Interface with automated systems for quality checks and production reporting.
8. Energy Management Systems
In energy management, accurate measurement of consumption is critical. These Panel Meters are used to:
- Energy Metering: Totalize pulses from two meters to track consumption for billing or audits.
- Distribution Control: Monitor totals from multiple sources for efficient load balancing and demand-response strategies.
- Data Logging: Record cumulative data for optimization and reporting in commercial or industrial facilities.
Conclusion
1/8 DIN Panel Meters for dual-channel pulse input totalizer are crucial tools in process automation, providing precise counting and totalization from two independent sources across industries like manufacturing, chemical processing, water treatment, food and beverage, pharmaceuticals, petrochemicals, packaging, and energy management. Their compact size, high-speed counting, and programmable features make them ideal for ensuring accurate event accumulation, reducing waste, and maintaining consistent quality in production. As industries continue to prioritize precision, automation, and compliance, these Panel Meters will remain essential for optimizing totalization operations and enhancing operational success.
Less Information...