Features
- ±0.2, ±2, ±20, ±200, ±300V & ±600V DC voltage ranges
- ±2, ±20, ±200 mA and ±5A DC current ranges
- Accuracy of 0.01% of reading ± 2 counts
- All input ranges are user selectable and factory calibrated
- Up to 60 conversions per second, Ideal for peak or valley capture
- Digital span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999
- Front panel scalable to ±99,999 for use with current shunts
- 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
- Transducer excitation output, 5, 10, 12, or 24 Vdc (isolated)
- Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
- Operating temperature from -40°C to 70°C (-40°F to 158°F)
- Wide choice of Plug-in-Play options:
- 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
- 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
- Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)
- Extended DPM allows up to 180 data points for custom curve linearization
and a rate derived from consecutive readings
Certificates of Compliance
Laureate™ 1/8 DIN Panel Meters for DC voltage and DC current meters
are programmable DC panel meters with a DC signal conditioner board. They combine high accuracy with high read rate and a wide range of (isolated) Plug-and-Play output option boards for computer interface and control. DC meter Accuracy of 0.01% of reading ± 2 counts.- DC voltmeter operation (selected by jumpers) provides and six full-scale DC voltage ranges from ±200.00 mV with 10 mV resolution to ±600.0V with 100 mV resolution. The 200.00 mV and 2.0000V ranges provide a high input impedance of 1 Gohm to minimize the load on the voltage signal.
- DC ammeter operation (selected by jumpers) provides four full-scale DC current ranges from ±2.0000 mA with 0.1 mA resolution to ±5.000 A with 1 mA resolution. The 5.000 A range measures the IR drop across a built-in 10 milliohm current shunt.
All signal conditioner board ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated panel meters. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.
The Optional Extended Laureate computer board enhances Laureate Panel Meters by displaying rates derived from successive readings and enabling highly accurate custom curve linearization. For example, it can calculate liquid volume or flow rate in a horizontal cylindrical tank using levels from a 4-20 mA transmitter. Setup is straightforward: users input up to 180 data points into a spreadsheet or text file, and the computer calculates spline-fit segments, which are then downloaded to the panel meters for precise operation.
Laureate Panel Meters are easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.
Scaling is from -99,999 to +99,999 (five full digits) with any decimal point to display readings in engineering units, such as PSI. Three scaling methods are user selectable: scale and offset, two-point method, and system-level calibration using actual transducer signals.
High read rate of up to 50 or 60 conversions per second, the Laureate™ Panel Meters use Concurrent Slope (US Pat. 5,262,780) analog-to-digital conversion to integrate signals over a full power line cycle (50 Hz or 60 Hz). This read rate enables peak and valley capture, real-time computer interfacing, and control applications. Peak and valley values are automatically captured and can be viewed using Laurel’s free Instrument Setup Software (compatible with Windows PCs) or transmitted as serial data.
- An unfiltered selection provides true peak and valley readings and aids in control applications.
- A batch average filter selection averages each 16 conversions.
- An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.
Two tare functions: auto-tare and manual tare. In auto-tare, an input line is grounded by an external pushbutton. This causes the current weight, which is normally the empty weight of the container to be stored in memory as an offset. In manual tare, the tare value can be entered manually via the front panel or a computer using Laurel's free Instrument Setup Software. For instance, the tare value may be the stated empty weight of a truck or rail car. Pressing the Reset button on the front panel toggles the display between gross weight (total weight on the scale) and net weight (gross weight with tare subtracted).
Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.
Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.
An (isolated) 5, 10, 12, or 24 Vdc excitation output is standard to power transducers or two-wire transmitters. Ratiometric operation, which automatically compensates for changes in the applied excitation, is jumper selectable for applications, such as bridges, where the signal to be measured is proportional to the excitation level.
DC Voltage
| DC Voltage Range | Resolution | Input Resistance | Error at 25°C |
|---|---|---|---|
| ±200.00 mV | 10 µV | 1 GΩ | 0.01% FS ± 2 cts |
| ±2.0000 V | 100 µV | 1 GΩ | 0.01% FS ± 2 cts |
| ±20.000 V | 1 mV | 10 MΩ | 0.01% FS ± 2 cts |
| ±200.00 V | 10 mV | 10 MΩ | 0.01% FS ± 2 cts |
| ±300.0 V | 0.1 V | 10 MΩ | ± 0.4 V |
| ±600.0 V* | 0.1 V | 10 MΩ | ± 0.4 V |
| * Range not ETL certified. | |||
| * For purposes of accuracy calculation, the 600V range is 2000V (20,000 counts). | |||
| Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. | |||
DC Current
| DC Current Range | Resolution | Input Resistance | Error at 25°C |
|---|---|---|---|
| ±2.0000 mA | 0.1 µA | 100 Ω | 0.01% FS ± 2 cts |
| ±20.000 mA | 1.0 µA | 10 Ω | 0.01% FS ± 2 cts |
| ±200.00 mA | 10 µA | 1 Ω | 0.01% FS ± 2 cts |
| ±5.000 A | 1 mA | 0.01Ω | ± 10 mA |
| * For purposes of accuracy calculation, the 5A range is 20A (20,000 counts). | |||
| Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. | |||
| Display | |
|---|---|
| Readout | 5 LED digits, 7-segment, 14.2 mm (.56"), red or green. |
| Range | -99999 to 99999 or -99990 to 99990 (count by 10) |
| Indicators | Minus sign, 2 red LED lamps |
| A-to-D Conversion | |
| Technique | Concurrent Slope™ (Pat 5,262,780) |
| A-to-D rate | 60/s at 60 Hz, 50/s at 50 Hz |
| Output update rate | 56/s at 60 Hz, 47/s at 50 Hz |
| Display update rate | 3.5/s at 60 Hz, 3/s at 50 Hz |
| Accuracy | |
| Error at 25°C | 0.01% FS ± 2 counts (except 5A range) |
| Span tempco | 0.003% of reading/°C |
| Zero tempco | 0.1 count/°C |
| Noise Rejection | |
| CMR, DC to 60 Hz | 130 dB |
| NMR at 50/60 Hz | 90 dB with min filtering |
| Maximum Signal | |
| Max applied voltage | 600 Vac for 20, 200 and 300 V ranges, 125 Vac for other ranges |
| Overcurrent protection | 25x for 2 mA, 8x for 20 mA, 2.5x for 200 mA, 1x for 5 A |
| Power Supply Boards (one required) | |
| Voltage, standard | 85-264 Vac or 90-300 Vdc |
| Voltage, optional | 12-32 Vac or 10-48 Vdc |
| Frequency | DC or 47-63 Hz |
| Power consumption (typical, base meter) | 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc, 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc |
| Power Isolation | 250V rms working, 2.3 kV rms per 1 min test |
| Excitation Output (standard) | |
| 5 Vdc | 5 Vdc ± 5%, 100 mA (jumper selectable) |
| 10 Vdc | 10 Vdc ± 5%, 120 mA (jumper selectable) |
| 12 Vdc | 12 Vdc ± 5%, 100 mA (jumper selectable) |
| 24 Vdc | 24 Vdc ± 5%, 50 mA (jumper selectable) |
| Output Isolation | 50 Vdc from signal ground |
| Analog Output Board (one optional) | |
| Output levels | 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (jumper selectable) |
| Current compliance | 2 mA at 10V (> 5 kΩ load) |
| Voltage compliance | 12V at 20 mA (< 600 Ω load) |
| Scaling | Zero and full scale adjustable from -99999 to +99999 |
| Resolution | 16 bits (0.0015% of full scale) |
| Step function response | 80 ms to 99% of final value (typ) |
| Isolation | 250V rms working, 2.3 kV rms per 1 min test |
| Relay Output Boards (one optional) | |
| Dual magnetic relays | 2 Form C, 10A max, 440Vac or 125Vdc max, 2500VA or 300W |
| Quad magnetic relays | 4 Form A (NO), 10A max, 440Vac or 125Vdc max, 2500VA or 300W |
| Dual solid state relays | 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
| Quad solid state relays | 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
| Relay commons | Isolated commons for dual relays or each pair of quad relays |
| Relay isolation | 250V rms working, 2.3 kV rms per 1 minute test |
| Step function response | 30 ms (typ) for contact relays, 25 ms (typ) for solid state relays |
| Relay latching modes | Latching or non-latching |
| Relay active modes | Active on or off, active high or low |
| Hysteresis modes | QA passband mode, split hysteresis, span hysteresis |
| Communication Boards (one optional) | |
| Board selections | RS232, RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, Ethernet, USB-to-RS485 gateway, Ethernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485 |
| Protocols | Laurel Custom ASCII (serial), Modbus RTU (serial), Modbus TCP (Ethernet or WiFi) |
| Digital addresses | 247 (Modbus), 31 (Laurel Custom ASCII), |
| Isolation | 250V rms working, 2.3 kV rms per 1 min test |
| Signal Connections | |
![]() |
|
| Environmental | |
| Operating temperature | -40°C to 70°C (-40°F to 158°F) |
| Storage temperature | -40°C to 85°C (-40°F to 185°F) |
| Relative humidity | 95% at 40°C, non-condensing |
| Protection | NEMA-4X (IP-65) when panel mounted |
| Mechanical | |
| Enclosure | 1/8 DIN, high impact plastic, UL 94V-0, color: black |
| Mounting | 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). |
| Dimensions | 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D) |
| Maximum panel thickness | 4.5 mm (0.18") |
| Tightening Torque - Connectors | Screw terminal connectors: 5 lb-in (0.56 Nm) |
| Tightening Torque - Pawls | Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm) |
| Weight of base meter | 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display) |
| Weight of option boards | 30 g (1.0 oz) typical per board (analog output, relay output, communications) |
| General | |
| Programming Methods | Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. |
| Security | Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper. |
| Warranty | 3 years parts & labor |
| Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. | |
Free Instrument Setup Software for Series 2 Laureates
Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.
- When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
- When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.
Download Free Instrument Setup Software
Installation
Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:
- Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
- Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
- Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
- Reboot your computer for the changed UAC setting to take effect.
RJ11-to-DB9 cable with rear view of DB9 connector to PC

RS232 cable, meter to PC, P/N CBL01
Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.
Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.
Meter Setup Screens
Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.
Meter Setup Utilities
From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: List, Plot and Graph.
- List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.
- Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
- Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.

Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays
Key Features
- Meets 1/8 DIN Standard.
- Installs from front of panel.
- Short depth behind the panel: only 4" (102 mm) plus connectors.
- Understated 0.157" (4 mm) thick bezel.
- Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
- Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
- Rugged GE Lexan® housing material.
- Safety certified per EN 61010-1.
Dimensions
Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter: 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).
Panel Mounting
Slide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel.
The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.
Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.
DC Digital Panel Meter Frequently Asked Technical Questions
CAL-Analog
Certificate of Calibration
$65.00DLS-XLOG2
XLog2 Data logging Software
$495.00IPC
Splashproof Cover
$48.00CON01
CON01 Connector
$75.00CBL01
RS232 Cable for Meters
$35.00CBL02
USB-to-RS232 Adapter Cable
$47.00CBL04
RS232 Cable for LT Transmitters
$47.00CBL05
USB Data Cable for Meters
$47.00CBL06
USB-to-RS485 Adapter Cable
$47.00CBL07
USB Programming & Data Cable
$47.00CBL08
RS485 Splitter Cable
$33.00Modular Design for Maximum Flexibility at Minimum Cost
All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boards, dual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.
The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Panel Meters.
Modular Hardware
The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for panel meters or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.
Connecting Laureate Panel Meters to a Local Area Network (LAN)
Up to 30 Laureate Panel Meters and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.
Flexible Communication Options for Panel Meters
Laureate Panel Meters can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.

Understanding 1/8 DIN Panel Meters for DC Voltage Input Signals
In industries and technical environments where stable electrical performance is critical, the ability to accurately measure and monitor DC voltage input signals directly influences system reliability, safety, and efficiency. The 1/8 DIN Panel Meters for DC Voltage Input Signals are compact, high-precision instruments engineered to deliver exact voltage measurements with clear digital readouts. These Panel Meters are indispensable in applications requiring reliable voltage monitoring — from power supply regulation to battery management and sensor interfacing. This overview explores their core functionality, standout features, technical advantages, and broad range of practical uses across modern industrial, commercial, and research settings.
What are 1/8 DIN Panel Meters?
1/8 DIN Panel Meters are compact electronic instruments designed to process input signals and display measurement data in a clear digital format. The "1/8 DIN" designation refers to their standardized physical size, defined by the Deutsches Institut für Normung (DIN), a German standards organization. This size measures approximately 48 mm × 96 mm (1.89 inches × 3.78 inches) on the front panel, making them an excellent fit for control panels, instrumentation enclosures, and operator stations where space is limited but accurate data presentation is critical. The standardized dimensions ensure compatibility with existing panel cutouts, simplifying installation, upgrades, and replacements in both new and legacy systems.
These Panel Meters serve as versatile tools for monitoring a variety of parameters — including voltage, current, temperature, frequency, and process values. Their digital displays, typically featuring LED or LCD technology with adjustable brightness, provide high visibility and readability even in challenging lighting or from a distance. This makes the Panel Meters dependable choices for operators who need quick, accurate data interpretation to support informed decision-making and process control.
What Do DC Voltage Input Panel Meters Do?
DC Voltage Input Panel Meters are built to measure the precise level of direct current voltage signals with exceptional accuracy. Depending on the model, they can handle input ranges from millivolts to hundreds of volts. This capability is vital in applications where stable DC voltage is required — for example, monitoring battery systems, regulating power supplies, or interfacing with sensors. By capturing the exact voltage level in real time, the Panel Meters help optimize system performance, diagnose electrical issues, ensure regulatory compliance, and improve overall operational quality.
For instance, in battery-powered equipment, the Panel Meters can track voltage drops to predict remaining capacity, while in power supply testing they can record stable output levels to verify compliance with specifications. Their precision makes them trusted tools for any application where voltage accuracy directly affects outcomes.
How Do 1/8 DIN Panel Meters for DC Voltage Input Work?
The operation of the 1/8 DIN Panel Meters for DC Voltage Input involves a carefully coordinated sequence of steps to deliver reliable and accurate measurements:
- Signal Acquisition
The Panel Meters receive DC voltage signals from external sources — such as power supplies, batteries, sensors, transducers, or control circuits — via dedicated input terminals. These inputs support a wide range of voltage levels and include protection against overvoltage or reverse polarity in many models. - High-Precision Signal Processing
Internal circuitry — often featuring isolation, filtering, and amplification — conditions the incoming voltage to eliminate noise and ensure stable readings. Advanced models apply sophisticated signal averaging and temperature compensation to maintain accuracy across varying environmental conditions. - Analog-to-Digital Conversion & Processing
The conditioned voltage is converted into a digital value by a high-resolution analog-to-digital converter (ADC). Scaling, unit conversion, and display formatting are applied to present the result in the desired units (volts, millivolts, etc.) with the appropriate number of decimal places for the specific application. - Display & Output Capabilities
The final value is shown on a bright, high-contrast digital display. Many models also provide programmable outputs — such as relays, open-collector transistors, analog signals (4–20 mA or 0–10 V), or communication interfaces (RS-232, RS-485, Modbus RTU/TCP, Ethernet) — to trigger external actions, log data, or integrate with PLCs, SCADA systems, or remote monitoring platforms.
Key Features of the 1/8 DIN Panel Meters for DC Voltage Input
The 1/8 DIN Panel Meters for DC Voltage Input include a wide array of features that enhance their performance, usability, and integration capabilities:
- Exceptional Voltage Accuracy
Offer resolution down to millivolts and accuracy typically better than ±0.1%, depending on the input range and calibration. This level of precision is essential for applications where small voltage variations can affect outcomes. - Clear, High-Visibility Displays
Feature large, backlit LED or LCD displays with adjustable brightness and contrast, allowing easy reading in bright, dim, or variable lighting conditions commonly found in industrial and laboratory environments. - Compact 1/8 DIN Form Factor
Fit standard panel cutouts, making them ideal for crowded control panels or retrofits without requiring major modifications to existing equipment layouts. - Flexible Input Compatibility
Support a broad range of DC voltage inputs (from ±50 mV to ±300 V or higher) with selectable scaling and overrange protection for versatile use across different systems. - Programmable Functions
Allow users to configure measurement ranges, display units, alarm thresholds, relay actions, scaling factors, and output behaviors to match specific application requirements and operational workflows. - Robust Industrial Design
Built to withstand harsh environments, with high IP front-panel protection, wide operating temperature range, and resistance to vibration, shock, dust, and electrical noise.
Benefits of Using 1/8 DIN Panel Meters for DC Voltage Input
Implementing 1/8 DIN Panel Meters for DC Voltage Input delivers numerous advantages across industrial and research applications:
- Enhanced System Reliability
Accurate voltage data helps maintain stable operation, reduce variations, and prevent faults, leading to higher uptime and lower maintenance costs. - Improved Accuracy & Repeatability
High-resolution measurements reduce errors in critical voltage applications, ensuring consistent results and better process control. - Cost-Effective Monitoring
The compact design and versatile features eliminate the need for multiple specialized voltmeters or monitors, reducing hardware costs and panel space requirements. - User-Friendly Operation
Intuitive interfaces, programmable settings, and clear digital displays make the Panel Meters accessible to operators with varying levels of technical expertise. - Scalability & Future-Proofing
Easy integration with communication protocols and external systems supports expansion into larger automation networks or Industry 4.0 environments. - Reliability in Harsh Conditions
Rugged construction ensures long-term performance in industrial settings with temperature extremes, vibration, dust, or electrical noise.
Technical Specifications (Typical)
Specifications vary by model, but typical 1/8 DIN Panel Meters for DC Voltage Input include:
- Input Range: ±50 mV to ±300 V (selectable scaling)
- Accuracy: ±0.1% of full scale or better
- Display: 4–6 digit LED or LCD with adjustable brightness
- Power Supply: 12–24 V DC or 85–265 V AC universal
- Communication: RS-232, RS-485, Modbus RTU/TCP, Ethernet (optional)
- Outputs: Relays, analog (4–20 mA or 0–10 V), open-collector
- Environmental Rating: IP65 front panel, wide operating temperature
Applications of 1/8 DIN Panel Meters for DC Voltage Input
The 1/8 DIN Panel Meters for DC Voltage Input are used in numerous sectors where exact voltage monitoring is critical:
- Industrial Automation & Robotics
Measure DC voltage in motors, actuators, sensors, and control circuits to optimize performance and prevent faults in assembly lines, robotic cells, and material handling systems. - Power Generation & Distribution
Monitor bus voltage, rectifier outputs, and battery banks in generators, UPS systems, and substations to ensure stable power delivery and grid reliability. - Renewable Energy Systems
Track DC voltage from solar panels, wind turbines, inverters, and battery storage to maximize energy harvest and system efficiency. - Automotive & Transportation
Monitor battery voltage, charging circuits, and auxiliary power in electric vehicles, rail systems, and heavy equipment for safety and performance. - Laboratory & Scientific Research
Provide precise voltage readouts in experimental setups, calibration benches, and test equipment for accurate data collection and validation. - Building Management & HVAC
Track control voltages in actuators, drives, and energy systems to optimize efficiency and support predictive maintenance. - Marine & Aerospace
Monitor DC power rails in navigation, propulsion, and life support systems under extreme conditions for safety and reliability. - Telecommunications
Monitor DC voltage in power supplies, battery backups, and equipment racks to ensure stable operation and prevent downtime in data centers and network hubs.
Conclusion
The 1/8 DIN Panel Meters for DC Voltage Input are compact, highly accurate, and versatile instruments that play a critical role in modern industrial, laboratory, and research environments. Their ability to deliver precise digital readouts of DC voltage, combined with robust construction, flexible inputs/outputs, and communication options, makes them essential tools for optimizing electrical systems, ensuring safety, and supporting innovation across diverse applications. Whether used in high-speed automation, renewable energy, transportation, or quality-critical testing, these Panel Meters provide reliable voltage data that drives efficiency, performance, and long-term system health.
Less Information...