Features
- Times single or cumulative events from 1 µs to 999,999 hrs
- Transmits single event time or accumulated time of all events
- Timing resolution to 0.2 µs
- Timing from 0.2 µs to 999,999 hrs
- Selectable HH.MM.SS clock format or 6-digit H, M or S decimal format
- Inputs from NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups down to 12 mV, or AC inputs up to 250 Vac
- Triggers on positive or negative pulse edges
- Digital span adjust from 0 to ±999,999, zero adjust from -999,999 to +999,999
- Front panel scalable: to ±999,999 for use with current shunts
- 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
- Transducer excitation output, 5, 10, 12, or 24 Vdc (isolated)
- Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
- Operating temperature from -40°C to 70°C (-40°F to 158°F)
- Wide choice of Plug-in-Play options:
- 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
- 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
- Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)
- Extended DPM includes rate and total simultaneously, dynamic up-down counting, arithmetic functions
Certificates of Compliance

The Laureate™ 1/8 DIN Panel Meters, 6-digit digital stopwatch and timer
can record single or cumulative events ranging from 1 µs to 999,999 hours, with a timing resolution as precise as 0.2 µs. It offers selectable time display formats in HH:MM:SS or 6-digit H, M, or S decimal format, accommodating a variety of measurement needs. Compatible with inputs from NPN or PNP proximity switches, contact closures, digital logic, magnetic pickups as low as 12 mV, and AC inputs up to 250 Vac, it triggers on both positive and negative pulse edges. The device operates on a broad power range of 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac with (isolated) transducer excitation output. It functions reliably in temperatures from -40°C to 70°C. Additionally, it offers a wide range of options including 2 or 4 relays (mechanical or solid-state, (isolated)), 1 or 2 analog outputs (isolated), and various communication interfaces such as Ethernet, WiFi, USB, RS232, and RS485 (isolated).- A-A Stopwatch Mode. Time can be measured between a start pulse and a stop pulse, both on Channel A, from either the positive or negative edges.
- A-B Stopwatch Mode. Time can also be measured between a start pulse on Channel A (positive or negative edge) and a stop pulse on Channel B (positive or negative edge). This mode allows inputs from different sources. In addition, the A and B inputs can be tied together to start the stopwatch with one polarity and stop it with the other polarity.
- Rate Based on 1/Time Mode. Highly accurate rate can be displayed by taking the inverse of time. Extensive arithmetic capabilities allow display in engineering units, such as meter/sec. This mode requires use of an Extended counter.
Display. The event time (Item #1) may be displayed as a decimal number with six-digit resolution. The longest single-event timing interval is 999,999 hours. The highest resolution is 0.2 µs. The event time may also be displayed in HH.MM.SS clock format with 1 s resolution. The stopwatch display is updated during timing at a rate controlled by a gate time, up to 25/s. It is reset to zero when the next start pulse occurs. Accumulated time from multiple events (Item #2) is also tracked and may be displayed up to 999,999 hours.
The FR dual-channel signal conditioner board accepts inputs from proximity switches with a PNP or NPN output, TTL or CMOS logic, magnetic pickups, contact closures, and other signals from 12 mV to 250 Vac. Jumper selections provide optimum operation for different sensor types and noise conditions. A built-in (isolated) 5, 10, 12, or 24 Vdc excitation supply can power proximity switches and other sensors, and eliminate the need for an external power supply.
Extended DPM includes rate and total simultaneously, dynamic up-down counting, arithmetic functions applicable to channels A & B (A+B, A-B, A/B, AxB, A/B-1), phase angle, power factor, duty cycle, batch control, custom curve linearization.
Laureate Panel Meters are easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.
All signal conditioner board ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated panel meters. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.
- An unfiltered selection provides true peak and valley readings and aids in control applications.
- A batch average filter selection averages each 16 conversions.
- An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.
Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.
Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.
An (isolated) 5, 10, 12, or 24 Vdc excitation output is standard to power transducers or two-wire transmitters. Ratiometric operation, which automatically compensates for changes in the applied excitation, is jumper selectable for applications, such as bridges, where the signal to be measured is proportional to the excitation level.
| Display | |
|---|---|
| Readout | 5 LED digits, 7-segment, 14.2 mm (.56"), red or green. |
| Range | -999,999 to +999,999 |
| Indicators | Four LED lamps |
| Inputs | |
| Types | AC, pulses from NPN, PNP transistors, contact closures, magnetic pickups. |
| Grounding | Common ground for channels A & B |
| Minimum Signal | Nine ranges from (-12 to +12 mV) to (+1.25 to +2.1V). |
| Maximum Signal | 250 Vac |
| Noise Filter | 1 MHz, 30 kHz, 250 Hz (selectable) |
| Contact Debounce | 0, 3, 50 ms (selectable) |
| Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. | |
| Stopwatch Mode | |
| Timing Modes: | |
| With Ch A only | + to + edge, or - to - edge. |
| With Ch A tied to Ch B | + to - edge, or - to + edge. |
| With Ch A and Ch B | + edge of A to + edge of B, + edge of A to - edge of B, |
| - edge to A to - edge of B, - edge of A to - edge of B | |
| Timing Interval | 1 µs to 999,999 hrs |
| Timing Resolution | 0.2 µs to 1 hr |
| Selectable Decimal Time | 999999 H, M or S format with decimal point |
| Selectable Clock Time | HH.MM.SS format |
| Output & Display Update | 0 ms + programmable from 10 ms to 199.99 s |
| Accuracy | |
| Time Base | Crystal calibrated to ±2 ppm |
| Span Tempco | ±1 ppm/°C (typ) |
| Long-term Drift | ±5 ppm/year |
| Power Supply Boards (one required) | |
| Voltage, standard | 85-264 Vac or 90-300 Vdc |
| Voltage, optional | 12-32 Vac or 10-48 Vdc |
| Frequency | DC or 47-63 Hz |
| Power Isolation | 250V rms working, 2.3 kV rms per 1 min test |
| Excitation Output (standard) | |
| 5 Vdc | 5 Vdc ± 5%, 100 mA (jumper selectable) |
| 10 Vdc | 10 Vdc ± 5%, 120 mA (jumper selectable) |
| 12 Vdc | 12 Vdc ± 5%, 100 mA (jumper selectable) |
| 24 Vdc | 24 Vdc ± 5%, 50 mA (jumper selectable) |
| Output Isolation | 50 Vdc from signal ground |
| Analog Output Boards (one optional) | |
| Output levels | 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (single-output option) |
| 4-20 mA, 0-20 mA, 0-10V (dual-output option) | |
| Current compliance | 2 mA at 10V ( > 5 kΩ load) |
| Voltage compliance | 12V at 20 mA (< 600 Ω load) |
| Scaling | Zero and full scale adjustable from -99999 to +99999 |
| Resolution | 16 bits (0.0015% of full scale) |
| Isolation | 250V rms working, 2.3 kV rms per 1 min test |
| (dual analog outputs share the same ground) | |
| Relay Output Boards (one optional) | |
| Dual magnetic relays | 2 Form C, 10A max, 440Vac or 125Vdc max, 2500VA or 300W |
| Quad magnetic relays | 4 Form A (NO), 10A max, 440Vac or 125Vdc max, 2500VA or 300W |
| Dual solid state relays | 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
| Quad solid state relays | 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
| Relay commons | Isolated commons for dual relays or each pair of quad relays |
| Relay isolation | 250V rms working, 2.3 kV rms per 1 minute test |
| Relay latching modes | Latching or non-latching |
| Relay active modes | Active on or off, active high or low |
| Hysteresis modes | QA passband mode, split hysteresis, span hysteresis |
| Communication Boards (one optional) | |
| Board selections | RS232, RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, Ethernet, USB-to-RS485 gateway, Ethernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485 |
| Protocols | Modbus RTU, Modbus ASCII, Modbus TCP (Ethernet), Laurel ASCII |
| Data rates | 300 to 19200 baud |
| Isolation | 250V rms working, 2.3 kV rms per 1 min test |
| Environmental | |
| Operating temperature | -40°C to 70°C (-40°F to 158°F) |
| Storage temperature. | -40°C to 85°C (-40°F to 185°F) |
| Relative humidity | 95% at 40°C, non-condensing |
| Protection | NEMA-4X (IP-65) when panel mounted |
| Electrical Connections | |
![]() |
|
| Mechanical | |
| Enclosure | 1/8 DIN, high impact plastic, UL 94V-0, color: black |
| Mounting | 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). |
| Dimensions | 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D) |
| Maximum panel thickness | 4.5 mm (0.18") |
| Tightening Torque - Connectors | Screw terminal connectors: 5 lb-in (0.56 Nm) |
| Tightening Torque - Pawls | Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm) |
| Weight of base meter | 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display) |
| Weight of option boards | 30 g (1.0 oz) typical per board (analog output, relay output, communications) |
| General | |
| Programming Methods | Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. |
| Security | Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper. |
| Warranty | 3 years parts & labor |
| Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. | |
Free Instrument Setup Software for Series 2 Laureates
Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.
- When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
- When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.
Download Free Instrument Setup Software
Installation
Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:
- Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
- Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
- Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
- Reboot your computer for the changed UAC setting to take effect.
RJ11-to-DB9 cable with rear view of DB9 connector to PC

RS232 cable, meter to PC, P/N CBL01
Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.
Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.
Meter Setup Screens
Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.
Meter Setup Utilities
From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: List, Plot and Graph.
- List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.
- Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
- Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.

Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays
Key Features
- Meets 1/8 DIN Standard.
- Installs from front of panel.
- Short depth behind the panel: only 4" (102 mm) plus connectors.
- Understated 0.157" (4 mm) thick bezel.
- Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
- Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
- Rugged GE Lexan® housing material.
- Safety certified per EN 61010-1.
Dimensions
Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter: 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).
Panel Mounting
Slide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel.
The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.
Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.
| Stopwatch Mode | |
|---|---|
![]() |
The stopwatch mode is used to time single events to one microsecond resolution between start and stop pulses on the same channel. The width of a single waveshape can be measured by tying the A and B channels together. |
| Timing Process Dynamics | |
![]() |
The start and stop pulses used for timing can be generated by the dual relay board in a Laureate analog panel meter or digital counter. For instance, the start and stop pulse edges can be created as temperature passes two alarm setpoints, or as temperature cycles in a hysteresis control mode. |
| Rate Based on 1 / Time | |
![]() |
The Extended stopwatch meter can be programmed to display highly accurate rate or speed based on time. For example photodetectors on Channels A and B can provide timing pulses as a fast-moving object breaks two light beams, and the meter can then display speed in engineering units such as ft/sec or m/sec. The display will be held until reset by an external control input. |
| Replacing an Oscilloscope with a Laureate Meter | |
![]() |
An oscilloscope is great for viewing and timing pulses in a lab. However, in fixed installations where digital timing accuracy and control outputs are required, a low-cost Laureate time interval meter will be the instrument of choice. Resolution to 0.2 µs is feasible. |
| Instrumenting a Pulsed Laser System | |
![]() |
|
| Some of the many possibilities in instrumenting a pulsed laser system with Laureate dual-channel counters: elapsed time, number of pulses, pulse width, pulse separation, duty cycle, and pulse rep rate. | |
CAL-Digital
Certificate of Calibration
$65.00DLS-XLOG2
XLog2 Data logging Software
$495.00IPC
Splashproof Cover
$48.00CON01
CON01 Connector
$75.00CBL01
RS232 Cable for Meters
$35.00CBL02
USB-to-RS232 Adapter Cable
$47.00CBL04
RS232 Cable for LT Transmitters
$47.00CBL05
USB Data Cable for Meters
$47.00CBL06
USB-to-RS485 Adapter Cable
$47.00CBL07
USB Programming & Data Cable
$47.00CBL08
RS485 Splitter Cable
$33.00Modular Design for Maximum Flexibility at Minimum Cost
All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boards, dual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.
The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Panel Meters.
Modular Hardware
The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for panel meters or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.
Connecting Laureate Panel Meters to a Local Area Network (LAN)
Up to 30 Laureate Panel Meters and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.
Flexible Communication Options for Panel Meters
Laureate Panel Meters can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.

Understanding 1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer
In industrial, laboratory, and commercial settings where precise timing is essential for operational efficiency, safety, and quality control, 1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer are specialized instruments designed to deliver accurate and reliable time measurements. These Panel Meters are critical in environments requiring detailed elapsed time tracking — from monitoring production cycles to timing experimental durations and synchronizing automated processes. Their high-resolution 6-digit display and robust functionality make them indispensable tools for applications demanding fine-grained timing data. This section explores their design, functionality, key features, technical advantages, and diverse applications across modern industrial and research environments.
What are 1/8 DIN Panel Meters?
1/8 DIN Panel Meters are compact electronic instruments designed to process input signals and display measurement data in a clear digital format. The "1/8 DIN" designation refers to their standardized physical size, defined by the Deutsches Institut für Normung (DIN), a German standards organization. This size measures approximately 48 mm × 96 mm (1.89 inches × 3.78 inches) on the front panel, making them an excellent fit for control panels, instrumentation enclosures, and operator stations where space is limited but accurate data presentation is critical. The standardized dimensions ensure compatibility with existing panel cutouts, simplifying installation, upgrades, and replacements in both new and legacy systems.
These Panel Meters serve as versatile tools for monitoring a variety of parameters — including voltage, current, temperature, frequency, and time intervals. Their digital displays, typically featuring LED or LCD technology with adjustable brightness, provide high visibility and readability even in challenging lighting or from a distance. This makes the Panel Meters dependable choices for operators who need quick, accurate data interpretation to support informed decision-making and process control.
What Do 6-Digit Digital Stopwatch and Timer Panel Meters Do?
6-Digit Digital Stopwatch and Timer Panel Meters are built to measure and display elapsed time with exceptional resolution, typically down to milliseconds or hundredths of a second. The 6-digit display allows precise tracking of durations up to 999,999 units (hours, minutes, seconds, or fractions), making them ideal for applications requiring detailed timing data. Stopwatch mode measures elapsed time from a start trigger, while timer mode counts up to or down from a preset value, supporting versatile use in both manual and automated scenarios.
For instance, in production environments, these Panel Meters can time machine cycles to identify inefficiencies, while in laboratory testing they can record the exact duration of chemical reactions or physical events to support reproducible results and data validation. Their precision makes them trusted tools for any application where timing accuracy directly affects outcomes.
How Do 1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer Work?
The operation of the 1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer involves a carefully coordinated sequence of steps to deliver reliable and accurate measurements:
- Signal Acquisition
The Panel Meters receive timing signals from external sources — such as proximity sensors, limit switches, photoelectric sensors, push buttons, or electrical pulses — or internal triggers for manual start/stop. These inputs are typically TTL, CMOS, dry contact, or open-collector signals, ensuring broad compatibility with industrial equipment and control systems. - High-Precision Time Processing
Internal timing circuitry — often driven by a stable quartz crystal oscillator or high-accuracy timebase — calculates elapsed time with exceptional resolution. Advanced models apply sophisticated noise filtering, debounce logic, and edge detection to eliminate false triggers and ensure stable, repeatable results even in electrically noisy environments or with mechanical contacts. - Digital Conversion & Processing
The measured time is converted into a digital value and processed by the Panel Meters' microcontroller. Scaling, unit conversion (hours/minutes/seconds or decimal), and display formatting are applied to present the result in the desired format with the appropriate number of decimal places for the specific application. - Display & Output Capabilities
The final value is shown on a bright, high-contrast 6-digit digital display. Many models also provide programmable outputs — such as relays, open-collector transistors, analog signals (4–20 mA or 0–10 V), or communication interfaces (RS-232, RS-485, Modbus RTU/TCP, Ethernet) — to trigger external actions, log data, or integrate with PLCs, SCADA systems, or remote monitoring platforms.
Key Features of the 1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer
The 1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer include a wide array of features that enhance their performance, usability, and integration capabilities:
- Exceptional Timing Resolution
Offer 6-digit readouts with resolution down to milliseconds or hundredths of a second, ensuring precise tracking of short or long durations in dynamic applications. - Clear, High-Visibility Displays
Feature large, backlit LED or LCD displays with adjustable brightness and contrast, allowing easy reading in bright, dim, or variable lighting conditions commonly found in industrial and laboratory environments. - Compact 1/8 DIN Form Factor
Fit standard panel cutouts, making them ideal for crowded control panels or retrofits without requiring major modifications to existing equipment layouts. - Flexible Trigger Compatibility
Support a broad range of start/stop/reset inputs (TTL, CMOS, dry contact, open-collector, rising/falling edge) for easy connection to sensors, switches, PLCs, or manual controls. - Programmable Functions
Allow users to configure timing modes (stopwatch/timer), display units, preset values, alarm thresholds, relay actions, and output behaviors to match specific application requirements and operational workflows. - Robust Industrial Design
Built to withstand harsh environments, with high IP front-panel protection, wide operating temperature range, and resistance to vibration, shock, dust, and electrical noise.
Benefits of Using 1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer
Implementing 1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer delivers numerous advantages across industrial and research applications:
- Enhanced Process Precision
Accurate timing data helps maintain uniform cycle times, reduce variations, and streamline operations, leading to higher quality and lower waste. - Improved Accuracy & Repeatability
High-resolution measurements reduce errors in critical timing applications, ensuring consistent results and better process control. - Cost-Effective Monitoring
The compact design and versatile features eliminate the need for multiple specialized timers or counters, reducing hardware costs and panel space requirements. - User-Friendly Operation
Intuitive interfaces, programmable settings, and clear digital displays make the Panel Meters accessible to operators with varying levels of technical expertise. - Scalability & Future-Proofing
Easy integration with communication protocols and external systems supports expansion into larger automation networks or Industry 4.0 environments. - Reliability in Harsh Conditions
Rugged construction ensures long-term performance in industrial settings with temperature extremes, vibration, dust, or electrical noise.
Technical Specifications (Typical)
Specifications vary by model, but typical 1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer include:
- Timing Resolution: Down to milliseconds or hundredths of a second
- Display Range: Up to 999,999 units (6 digits)
- Input Types: TTL, CMOS, dry contact, open-collector, rising/falling edge
- Display: 6-digit LED or LCD with adjustable brightness
- Power Supply: 12–24 V DC or 85–265 V AC universal
- Communication: RS-232, RS-485, Modbus RTU/TCP, Ethernet (optional)
- Outputs: Relays, analog (4–20 mA or 0–10 V), open-collector
- Environmental Rating: IP65 front panel, wide operating temperature
Applications of 1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer
The 1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer are used in numerous sectors where exact timing is critical:
- Industrial Automation & Robotics
Measure cycle times, dwell periods, and synchronization intervals in assembly lines, robotic cells, packaging machines, and material handling systems to optimize throughput and reduce waste. These Panel Meters are especially valuable in high-speed production where even small timing variations can affect product quality or machine performance. - Testing & Quality Assurance
Evaluate response times of relays, solenoids, valves, and electronic components in R&D, production testing, and incoming inspection to ensure compliance with design specifications and industry standards. - Laboratory & Scientific Research
Record precise intervals in chemical reactions, physical experiments, or biological assays to support reproducible results and data integrity. The Panel Meters' high resolution makes them ideal for time-sensitive scientific studies. - Process Monitoring & Batch Control
Track durations of process steps (e.g., mixing, curing, drying, or filling) to maintain consistency, detect anomalies, and improve overall production quality in batch-oriented manufacturing. - Telecommunications & Networking
Measure signal propagation delays or synchronization intervals to optimize network performance and troubleshoot timing issues in communication systems. - Automotive & Aerospace Testing
Monitor timing in engine cycles, ignition events, or actuator response during development, testing, and maintenance to ensure safety and performance.
Where Are 1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer Used?
1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer are deployed in environments where reliable, high-precision timing is essential for process control, safety, and quality. Their compact size, accuracy, and robust features make them a cornerstone in industrial, laboratory, and commercial settings. Below is a detailed exploration of the primary industries and use cases for these Panel Meters.
1. Industrial Automation
In industrial automation, these Panel Meters provide real-time timing data for coordinated machinery operations. They ensure optimal performance and reduce waste in automated systems like robotic assembly lines or chemical reactors.
2. Manufacturing
Manufacturing processes, including metal treatment, plastics extrusion, and food production, rely on precise timing control. These Panel Meters monitor cycle durations in ovens, presses, or extruders to maintain consistent product quality and prevent defects.
3. Laboratories
In research laboratories, these Panel Meters track timing in test rigs, environmental chambers, or simulation equipment. Their high accuracy ensures controlled conditions for experiments in chemistry, biology, or materials science.
4. HVAC Systems
Heating, ventilation, and air conditioning (HVAC) systems use these Panel Meters to monitor operational intervals for compressors, fans, or pumps. Accurate timing optimizes energy use and maintains indoor comfort.
5. Automotive Industry
In automotive manufacturing and testing, these Panel Meters monitor timing in engine test stands or assembly processes. They ensure optimal performance and compliance with standards in vehicle production.
6. Energy and Utilities
In energy systems, these Panel Meters track operational durations in turbines, pumps, or valves to ensure efficient operation and prevent failures in power generation or distribution.
7. Aerospace and Defense
In aerospace and defense, where precision and reliability are critical, these Panel Meters monitor timing in test equipment, simulators, or control systems. Their accurate readings ensure operational safety and performance in demanding conditions.
8. Food and Beverage Industry
In food processing, these Panel Meters ensure precise timing control in ovens, mixers, or pasteurizers, maintaining product quality and compliance with regulations.
Conclusion
1/8 DIN Panel Meters for a 6-Digit Digital Stopwatch and Timer are versatile tools with applications spanning industrial automation, manufacturing, laboratories, HVAC systems, automotive, energy, aerospace, and food and beverage industries. Their compact size, high accuracy, and robust features make them essential for precise timing monitoring and control. By providing reliable data, these Panel Meters ensure operational efficiency, safety, and quality across diverse sectors, solidifying their role in modern industrial and scientific applications.
Less Information...