Laurel Electronics
Marca +52 (444) 548 2052 para Asistencia en México

ventas@laurelsmexico.com
Panel Meters - Counters - Timers - Transmitters, 4-20 mA & Modbus - Ethernet - USB - RS485 - RS232

Digital Panel Meters & Controllers for Process, Level, Strain, Pressure, Flow, Rate, RPM, 4-20 mA

Product Selection Guide

Laurel Digital Process Panel Meter

Laureate Process Meter, Model P

5-digit DC digital panel meter for analog signals such as 0-10 mA, 4-20 mA or 0-10 V. Programmable zero and span using three methods:scale and offset, two-points, or system-level calibration using actual transducer signals for known readings. Fast read rates with peak hold. An Extended processor version allows custom curve linearization and rate from successive analog readings. Fast read rates with peak hold. Includes isolated transducer excitation supply. Optional analog output, relays, and data I/O. Five 0.56" (14.2 mm) high digits, 1/8 DIN case.
Laurel Process Totalizer for Analog Signals

Laureate Process Totalizer, Model VF

This digital panel meter totalizes 0-1 mA, 4-20 mA or 0-10 V analog signals, for example to display totalized volume from the 4-20 mA analog signal of a flow meter transducer. Capabilities include zero and span adjustment, square root extraction from differential flow meter signals, custom curve linearization, and elapsed time based on rate (for example, the time it will take to fill a tank at the current flow rate. Optional data I/O and relays for alarm or control. Six 0.56" (14.2 mm) high digits, 1/8 DIN case.
Laurel Strain Gauge & Potentiometer Follower Meter

Laureate Strain Gauge & Potentiometer Follower Meter, Model SG

5-digit DC digital panel meter for application where the signal is a changing resistance. A built-in isolated 10 Vdc excitation supply powers four 350-ohm load cells in parallel. Ratiometric operation with 4-wire bridge connection cancels variations in the excitation supply. Most sensitive full-scale input is ±200 mV. Multiple selectable filtering methods assure a stable display. Programmable zero and span using three methods: scale and offset, two-points, and system-level calibration using actual transducer signals. Auto-tare with tare value stored in memory for weighing applications. Optional analog output, relays, and data I/O. Five 0.56" (14.2 mm) high digits, 1/8 DIN case.
 Laurel Pulse Input Rate Meter

Laureate Pulse Input Rate Meter, Model FR

6-digit scalable counter with dual inputs from a wide range of pulse signal sources. Ideal as a tachometer or flow meter display. Allows square root extraction, custom curve linearization, and display of rate or total. Dual channels allow addition or subtraction of two rates or taking the ratio of two rates, for example to display draw (Ch A  / Ch B - 1). Includes isolated transducer excitation supply. Fast read rates with peak hold. Optional analog output, relays, and data I/O. Six 0.56" (14.2 mm) high digits, 1/8 DIN case.
Magna Series Large Digit Digital Panel Meters and Remote Displays

MAGNA Series Large Digit Displays

Available with 4 or 6 digits and a digit height of 2.2" (57 mm), 4" (102 mm), 6" (150 mm), or 8" (200 mm) for long viewing distances. Available for process signals, rate / frequency, temperature, and more. Includes transducer excitation supply. Optional dual 5A relays, analog output, and serial data output. Choice of display brightness and cases for indoor or outdoor mounting.
Microminiature Digital Process Meter, Model M-35

Microminiature Digital Process Meter, Model M-35

Fits 22.5 x 45 mm cutout. Accepts 4-20 mA, 0-10 mA, 0-2V, 1-5 V, or 0-10 V signals. 3-1/2 0.39" (10 mm) high digits. Powered from 10-30 Vdc.
Digital panel meter used for flowmeter readout for flow rate or totalized flow

Transducers for flow or batch control may put out a pulsed / AC signal or a conditioned analog signal such as 0-1 mA, 4-20 mA or 0-10 V. Laurel offers digital panel meters for all signal types normally associated with flow meters, with scaling to display in engineering units, such as Gallons, GPM, or liters/sec. Flow meter capabilities include square root extraction for use with differential pressure flow meters, custom curve linearization, rate from successive readings, totalizing from rate signals, analog outputs tied to the reading, and relay outputs for alarm or control.

Flow meter readout for flow rate or totalized flow is a major application of Laureate panel meters and counters. The Laureate Model FR dual-channel pulse input counters can display flow rate, totalized flow, the ratio of two flows, or the ratio of two totals to control mixing. It can also display the sum of two flows (for total flow) or the difference of two flows (for net flow). The Laureate Model VF can display flow rate or totalized flow for 4-20 mA, 0-1 mA or 0-10 V analog signals.

Legal Information
seal-20th24    
facebook   G+   twitter   linkedin
© 1990-2024 Laurel Electronics
feedback