Features
- 6-digit display of rate or totalized rate, totalizer flow meter, field scalable
- High accuracy: ±0.005% of span ±1 count
- 0-1 mA, 4-20 mA or 0-10 V analog signal to a frequency of 10 kHz to 110 kHz
- Converts signal input to a scaled rate or totalized rate
- Selectable square root for differential flow
- Output accuracy maintained for narrow or wide spans
- Extracts square root from differential pressure flow transducers & flow totalizer
- All input ranges are user selectable and factory calibrated
- Digital span adjustment: 0 to ±999,999; zero adjustment: -999,999 to +999,999
- Front panel scalable: 0 to ±999,999 for use with current shunts
- 1/8 DIN size with bright red or green 0.56" (14.2mm), high LED digits
- Transducer excitation output, 5, 10, 12, or 24 Vdc (isolated)
- Power 85-264 Vac / 90-300 Vdc or 10-48 Vdc / 12-32 Vac (isolated)
- Operating temperature from -40°C to 70°C (-40°F to 158°F)
- Wide choice of Plug-in-Play options:
- 2 or 4 relays, mechanical or solid state, for alarm or control (isolated)
- 1 or 2 Analog output, 4-20 mA, 0-20 mA, 0-10V, or -10V to +10V (isolated)
- Communications: Ethernet, WiFi, USB, RS232, RS485 (isolated)
- Extended DPM allows up to 180 data points for custom curve linearization, time based on rate, batch control
The Laureate™ 1/8 DIN Digital Panel Meter is a six-digit display of rate or total at the push of a front panel key.
A Laureate with the Standard counter main board and a VF voltage-to-frequency signal conditioner board can be scaled to display rate or totalized rate to six digits for 0-1 mA, 4-20 mA or 0-10V analog process signals to a frequency of 10 kHz to 110 kHz. Special input ranges are available from the factory. For example, the display can be scaled to show flow rate in gallons/minute or liters/sec, or to show volume in gallons or liters from the 0-10V output of a flow transducer. Or the display can be scaled to display power consumption in kilowatts or total utilized energy in kilowatt-hours based on the 0-1 mA output of a watt transducer.- Square root extraction is selectable and can be applied to rate or total. This makes the VF Laureate ideal for use with differential pressure flow meters, which have a squared output. Totalized volume is based on linearized rate.
- Accuracy is one of the highest for any digital panel meter: ±0.005% of span ±1 count.
Laureate Digital Panel Meters are easily programmed with Laurel’s free Instrument Setup Software, downloadable from our website and compatible with Windows PCs, requiring a data interface board for setup.
All signal conditioner board ranges are factory-calibrated, with calibration factors for each range securely stored in an onboard EEPROM. These factors can be scaled via software to accommodate external shunts, enabling field replacement of signal conditioner boards without necessitating recalibration of the associated digital panel meter. For optimal accuracy, factory recalibration is recommended annually. All Laurel Electronics instruments undergo factory calibration using the industry-leading Fluke calibrators, which are recalibrated yearly and certified traceable to national standards, ensuring the highest level of precision and reliability.
Extended DPM Counter Version
- Batch control based on linearized total. A Laureate VF meter with the Extended counter main board can totalize linearized flow from an analog rate signal, and also count up to a preset value, or count down to zero from a preset value for batch control. Operation as a batch controller requires the dual-relay output board option. One of the relays is dedicated to ON/OFF batch control. The other relay is available to slow down rate near the setpoint or to provide another alarm or control function based on rate or total.
- Custom Curve Linearization. For custom curve linearization, up to 180 data points can be input into a spreadsheet or text file by the user. The computer then calculates spline-fit segments, which are downloaded into the meter via RS232. The Extended VF meter can linearize and display analog inputs based on a custom curve, for instance to read out the volume of an irregularly shaped tank based on level or pressure, or to linearize a nonlinear transducer. Custom-linearized rates can also be totalized and be used for batch control.
- Time Based on Rate. The Extended VF meter can display a time inversely proportional to measured rate, such as the time that it will take a conveyor to traverse an oven. As the rate of the conveyor is increased, the displayed baking time is decreased.
Principles of V-to-F Operation
The V-to-F signal conditioner board converts the full-scale 0-1 mA, 4-20 mA or 0-10 V analog signal to a frequency of 10 kHz to 110 kHz. This frequency is determined by measuring period over a selected gate time (from 10 ms to 200 s) and taking the inverse of period. Selecting a short gate time provides a much higher update rate than conventional counting-type frequency meters. At the lowest frequency of 10 kHz and the minimum gate time of 10 ms, the meter is capable of 25 updates per second. Scaling to rate in engineering units and totalizing are done mathematically. Totals are calculated as the product of rate and time in seconds regardless of the selected gate time. Totals are stored in nonvolatile memory in case of power loss.
High Resolution Display
The display of rate or total may be scaled to ±999,999. The two least-significant digits may be set to display zero with rounding or be active digits. Noise in rate readings can be reduced by selecting a longer gate time. In addition, an adaptive digital filter can reduce variations due to noise while rapidly responding to actual changes in signal level.
- An unfiltered selection provides true peak and valley readings and aids in control applications.
- A batch average filter selection averages each 16 conversions.
- An adaptive moving average filter selection provides a choice of 8 time constants from 80 ms to 9.6 seconds. When a significant change in signal level occurs, the filter adapts by briefly switching to the shortest time to follow the change, then reverts back to its selected time constant. An Auto setting selects the time constant selection based on signal noise.
Peak and valley values are automatically captured. These may be displayed via a front panel pushbutton command or control signal at the rear connector, or be transmitted as serial data.
Two rear panel control Inputs (CMOS/TTL levels, logic 0 = tied to digital ground, logic 1 = open) or dry contacts that can be set to control / activate 14 meter commands.
An (isolated) 5, 10, 12, or 24 Vdc excitation output is standard to power transducers or two-wire transmitters. Ratiometric operation, which automatically compensates for changes in the applied excitation, is jumper selectable for applications, such as bridges, where the signal to be measured is proportional to the excitation level.
Modular Design for Maximum Flexibility at Minimum Cost
All boards are isolated from meter and power grounds. Optional Plug-in-Play boards for communications and control include Ethernet, WiFi, serial communication boards, dual or quad relay boards, and an analog output board. Laureates may be powered from 85-264 Vac or optionally from 12-32 Vac or 10-48 Vdc. The display is available with bright red or green 0.56" (14.2mm) high LED digits. The 1/8 DIN case meets NEMA 4X (IP65) specifications from the front when panel mounted. Any setup functions and front panel keys can be locked out for simplified usage and security. A built-in 5, 10, 12, or 24 Vdc excitation supply can power transducers, eliminating the need for an external power supply. All power and signal connections are via UL / VDE / CSA rated screw clamp plugs.
The Laureate™ Series features modular design with up to 7 isolated plug-in boards, applicable to all Laureate 1/8 DIN Digital Panel Meters.
Modular Hardware
The design of the Laureate™ Series is modular for maximum flexibility at minimum cost. All boards are isolated from meter and power grounds. The base configuration for a panel meter or counter consists of a main module (with computer and plug-in display boards), a power supply board, and a signal conditioner board. Optional plug-in-play boards include an isolated setpoint controller board, an isolated analog output board, and an isolated digital interface board. Modular design and a choice of plug-in options allow the Laureate to be customized for a broad range of applications from simple monitoring to control and computer interface. There can be up to five plug-in boards in a 1/8 DIN Laureate.

Connecting Laureate Digital Panel Meters to a Local Area Network (LAN)
Up to 30 Laureate Digital Panel Meters and/or LT Transmitters can be configured for RS485 and daisy-chained to an LT Transmitter using Laurel’s High Speed Ethernet-to-RS485 converter board for seamless LAN integration. Alternatively, Laurel LTE series Ethernet transmitters can connect directly to a LAN via an Ethernet cable. Setup for both configurations is streamlined using Laurel’s free Instrument Setup Software, which simplifies node discovery and transmitter configuration.
Flexible Communication Options for Digital Panel Meters
Laureate Digital Panel Meters can be equipped with Laurel communication boards to support various interfaces and protocols. These include serial interfaces with ASCII or Modbus RTU protocols, and Ethernet interfaces with web access, ASCII, or Modbus TCP/IP protocols, ensuring versatile connectivity for your commercial applications.
Display | |
---|---|
Readout | 6 LED digits, 7-segment, 14.2 mm (.56") |
Color | Red or green LED |
Range | -999,999 to +999,999 |
Indicators | Four LED lamps |
Inputs | |
Standard signal levels | 4-20 mA, 0-1 mA, 0-10V (jumper selectable) |
Input resistance | 50Ω at 4-20 mA, 1.00 kΩ at 0-1 mA, 1.01 MΩ at 0-10V |
Other signal levels | Consult factory |
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. | |
Conversion | |
Frequency Technique | Inverse period |
Update Rate | Gate time + 30 ms (max) |
Gate Time | Selectable 10 ms to 199.99 s |
Accuracy | |
Span tempco | ±0.003% reading/°C |
Zero tempco | ±0.003% FS/°C |
Accuracy at 25°C | ±0.01% FS ± 1 count |
Power Supply Boards (one required) | |
Voltage, standard | 85-264 Vac or 90-300 Vdc |
Voltage, optional | 12-32 Vac or 10-48 Vdc |
Frequency | DC or 47-63 Hz |
Power consumption (typical, base meter) | 1.2W @ 120 Vac, 1.5W @ 240 Vac, 1.3W @ 10 Vdc, 1.4W @ 20 Vdc, 1.55W @ 30 Vdc, 1.8W @ 40 Vdc, 2.15W @ 48 Vdc |
Power Isolation | 250V rms working, 2.3 kV rms per 1 min test |
Excitation Output (standard) | |
5 Vdc | 5 Vdc ± 5%, 100 mA (jumper selectable) |
10 Vdc | 10 Vdc ± 5%, 120 mA (jumper selectable) |
12 Vdc | 12 Vdc ± 5%, 100 mA (jumper selectable) |
24 Vdc | 24 Vdc ± 5%, 50 mA (jumper selectable) |
Output Isolation | 50 Vdc from signal ground |
Analog Output Boards (one optional) | |
Output levels | 4-20 mA, 0-20 mA, 0-10V, -10 to +10V (single-output option) |
4-20 mA, 0-20 mA, 0-10V (dual-output option) | |
Current compliance | 2 mA at 10V ( > 5 kΩ load) |
Voltage compliance | 12V at 20 mA (< 600 Ω load) |
Scaling | Zero and full scale adjustable from -99999 to +99999 |
Resolution | 16 bits (0.0015% of full scale) |
Isolation | 250V rms working, 2.3 kV rms per 1 min test |
(dual analog outputs share the same ground) | |
Relay Output Boards (one required for batch control) | |
Dual magnetic relays | 2 Form C, 10A max, 440Vac or 125Vdc max, 2500VA or 300W |
Quad magnetic relays | 4 Form A (NO), 10A max, 440Vac or 125Vdc max, 2500VA or 300W |
Dual solid state relays | 2 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
Quad solid state relays | 4 Form A (NO), AC or DC, 0V - 400V, 120Ma, 35Ohms (max at On-State) |
Relay commons | Isolated commons for dual relays or each pair of quad relays |
Relay isolation | 250V rms working, 2.3 kV rms per 1 minute test |
Relay latching modes | Latching or non-latching |
Relay active modes | Active on or off, active high or low |
Hysteresis modes | QA passband mode, split hysteresis, span hysteresis |
Communication Boards (one optional) | |
Board selections | RS232, RS485 with dual RJ11 connectors, RS485 with dual RJ45 connectors, USB, Ethernet, USB-to-RS485 gateway, Ethernet-to-RS485 gateway, WiFi with built-in antenna plus USB & RS485, WiFi with external antenna plus USB & RS485 |
Protocols | Laurel Custom ASCII (serial), Modbus RTU (serial), Modbus TCP (Ethernet or WiFi) |
Digital addresses | 247 (Modbus), 31 (Laurel ASCII), |
Isolation | 250V rms working, 2.3 kV rms per 1 min test |
Environmental | |
Operating temperature | -40°C to 70°C (-40°F to 158°F) |
Storage temperature. | -40°C to 85°C (-40°F to 185°F) |
Relative humidity | 95% at 40°C, non-condensing |
Protection | NEMA-4X (IP-65) when panel mounted |
Electrical Connections | |
![]() |
|
Mechanical | |
Enclosure | 1/8 DIN, high impact plastic, UL 94V-0, color: black |
Mounting | 1/8 DIN panel cutout required: 3.622" x 1.772" (92 mm x 45 mm). |
Dimensions | 4.68" x 2.45" x 5.64" (119 mm x 62 mm x 143 mm) (W x H x D) |
Maximum panel thickness | 4.5 mm (0.18") |
Tightening Torque - Connectors | Screw terminal connectors: 5 lb-in (0.56 Nm) |
Tightening Torque - Pawls | Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm) |
Weight of base meter | 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display) |
Weight of option boards | 30 g (1.0 oz) typical per board (analog output, relay output, communications) |
General | |
Programming Methods | Four front panel buttons or via Laurel's free Instrument Setup Software, which runs on a PC under MS Windows. |
Security | Lockout options include using the front panel buttons, the free Instrument Setup Software, or a hardware jumper. |
Warranty | 3 years parts & labor |
Recalibration: All ranges are calibrated at the factory. Recalibration is recommended every 12 months. |
Free Instrument Setup Software for Series 2 Laureates
Free Downloadable Windows-based Instrument Setup (IS) software (Data Interface Board Required) for use with our programmable Digital Panel Meters, Scale Meters, Counters, Timers, Remote Displays, and Transmitters, are an easy method to set up Laureate 1/8 DIN digital panel meters, counters, timers, remote displays, and DIN-rail transmitters, as explained in the Instrument Setup Software Manual. Laureate 1/8 DIN instruments can also be set up from the front panel, as explained in their respective Owners Manuals. Instrument Setup software is of benefit whether or not the PC is connected to the instrument.
- When the PC is connected to the instrument, Instrument Setup software can retrieve the setup file from the instrument or open a default setup file or previously saved setup file from disk View Setup, then provides graphical user interface (GUI) screens with pull-down menus applicable to input, display, scaling, filtering, alarms, communications, analog output, and front panel lockouts. Fields that are not applicable to the instrument as configured are either left out or grayed out. Clicking on any item will bring up a detailed Help screen for that item. After editing, the setup file can be downloaded, uploaded to the instrument, or saved to a disk. The same setup file can then be downloaded into multiple instruments.
- When the PC is not connected to the instrument, the above GUI screens can be used to set up a virtual instrument. The setup file can then be saved to disk. Switching toView Menu then brings up a screen with the required front panel programming steps. This view can be printed out for use at the instrument site and to serve as a hard copy record.
Download Free Instrument Setup Software
Installation
Set User Account Control (UAC) of MS Windows to "Never notifiy me" so that Instrument Setup Software can create directories. The UAC change screen can be reached as follows:
- Under Windows 7, click on the Windows Start button in the lower left of the desktop and enter "UAC" in the search field.
- Under Windows 8, navigate to Control Panel, then to the "User Accounts and Family Safety" section, and click on "Change User Account Control Settings."
- Under Windows 10, click on the Windows Start button in the lower left of the desktop, then on "Settings", and enter "UAC" in the search field.
- Reboot your computer for the changed UAC setting to take effect.

RJ11-to-DB9 cable with rear view of DB9 connector to PC

RS232 cable, meter to PC, P/N CBL01
Laureate 1/8 DIN Laureate instruments must be equipped with a serial communications board and be connected to the computer via a serial communications cable. The connection can be via RS232, RS485, USB or Ethernet. Following setup, the serial communications board may be removed from the instrument if desired. The wiring of the RS232 cable is illustrated above with end views of the two connectors.
Laureate LT Series transmitters come standard with a 3-wire serial interface, which can be jumpered for RS232 or RS485.
Laureate LTE Series transmitters come standard with an Ethernet interface.
Meter Setup Screens
Click on any of the reduced screens below for a full-size screen view, then click on the Back button of your browser to return to this page. The screens examples below are for a fully-loaded Series 2 Digital Panel Meter (DPM), which is connected to the PC via RS232. If the meter is a Series 1 meter (pre-2007), this is sensed by the software, and somewhat different screens are brought up. Please see Series 1 setup screens.











Meter Setup Utilities




From the Main Menu, click on Readings if your PC is connected to the meter. A pull-down menu then offers three choices: List, Plot and Graph.
- List presents the latest readings in a 20-row by 10-column table. Press Pause at any time to freeze the display. This is one method to capture peak readings.
- Plot generates a plot of readings vs. time in seconds. It effectively turns the DPM-PC combination into a printing digital oscilloscope.
- Graph generates a histogram where the horizontal axis is the reading and the vertical axis is the number of occurrences of readings. The display continually resizes itself as the number of readings increases.


Laureate™ 1/8 DIN Case For Laureate Digital Panel Meters, Counters, Timers & Remote Displays

Key Features
- Meets 1/8 DIN Standard.
- Installs from front of panel.
- Short depth behind the panel: only 4" (102 mm) plus connectors.
- Understated 0.157" (4 mm) thick bezel.
- Meets NEMA 4X (IP-65) for high-pressure wawshdon when panel mounted.
- Screw clamps connectors meet VDE / IEC / UL / CSA safety standards.
- Rugged GE Lexan® housing material.
- Safety certified per EN 61010-1.
Dimensions

Maximum panel thickness: 4.5 mm (0.18")
Weight of base meter: 210 g (7.4 oz) typical (DPM, counter, timer, 6-digit remote display)
Weight of option boards: 30 g (1.0 oz) typical per board (analog output, relay output, communications)
Tightening Torque - Connectors: Screw terminal connectors: 5 lb-in (0.56 Nm)
Tightening Torque - Pawls: Digital Panel Meter Case Pawls: 5 lb-in (0.56 Nm)
Dimensioned CAD assembly drawings in EPRT, STEP, x_t. dwg, pdf file formats: Laureate-meter-case.zip (zipping prevents browser from opening CAD files as text files).
Panel Mounting
Slide the meter into a 45 x 92 mm 1/8 DIN panel cutout. Ensure that the provided gasket is in place between the front of the panel and the back of the meter bezel.
The meter is secured by two pawls, each held by a screw, as illustrated. Turning each screw counterclockwise extends the pawl outward from the case and behind the panel. Turning each screw clockwise further tightens it against the panel to secure the meter.
Turning each screw counterclockwise loosens the pawl and retracts it into its well. This position allows installed meter to be removed from their panel, or new meters to be installed in a panel. Do not remove the screws from their pawls. Doing so would cause the screw and pawl to fall off and likely get lost. Do not overtighten so as not to damage the plastic parts.
Flow from a Differential Pressure Transducer | |
---|---|
![]() |
An ideal application for the Standard Laureate VF meter: readout of flow based on the 4-20 mA analog signal from a differential pressure transducer. Options include dual relays for alarm or control, isolated analog output to turn the meter into a transmitter, and RS232/485 data communications.s |
Up- or Down-Counting Batch Controller | |
![]() |
An ideal application for the Extended Laureate VF meter: up- or down-counting batch controller. The dual-relay card is required. One relay is dedicated to batch control, the other relay is available to alarm the rate or total. The signal input can be linear or nonlinear. The display can be toggled between rate and total. |
Volume of an Irregularly-Shaped Tank | |
![]() |
The Extended Laureate VF meter can linearize analog signals for display and alarm using custom curve linearization with multiple nonlinear segments. As illustrated, tank level is measured by an ultrasound detector, which transmits a 4-20 mA signal. This signal is then converted to a highly accurate volume reading. Linearized readings can also be totalized. |
Process Time from an Analog Rate Signal | |
![]() |
A unique application of the Extended Laureate VF meter is displaying process time based on the 4-20 mA or 0-10 V signal from a rate meter. In this example, a tachometer transmits the speed of a conveyer belt through an oven. The meter displays baking time in the oven using the mathematical relationship time = distance / speed. |
IPC
Splashproof Cover
CLB01
RS232 Cable for Meters
CLB02
USB-to-RS232 Adapter Cable
CBL04
RS232 Cable for LT Transmitters
CLB05
USB Data Cable for Meters
CLB06
USB-to-RS485 Adapter Cable
CLB07
USB Programming & Data Cable
CLB08
RS485 Splitter Cable
BKBD
RS485 RJ11 Terminal Block Adapter
Understanding the 1/8 DIN Panel Meter for 6-Digit Analog Input Totalizer & Process Meter
Introduction
In industrial automation and process control, precise measurement is fundamental to ensuring efficiency, safety, and quality. From monitoring temperature and pressure to tracking flow rates or energy consumption, accurate data drives informed decision-making. The 1/8 DIN Panel Meter for 6-Digit Analog Input Totalizer & Process Meter is a specialized instrument designed to provide reliable measurement, display, and totalization of analog input signals, making it an essential tool across diverse industrial applications.
What is a 1/8 DIN Panel Meter?
A 1/8 DIN Panel Meter is a compact electronic device adhering to the standardized dimensions set by the Deutsches Institut für Normung (DIN), a German standards organization. Measuring approximately 96 mm x 48 mm, this meter is ideal for integration into control panels with limited space, offering a clear and robust display for critical process data. Its standardized size ensures compatibility with existing systems, simplifying installation and upgrades.
6-Digit Display
The 6-digit display is a defining feature of this Panel Meter, enabling high-precision measurement and readability. Capable of displaying values up to 999,999, it captures even minor variations in input signals, making it suitable for applications where detailed and accurate data is crucial. The bright, easy-to-read display ensures operators can quickly interpret measurements, even in challenging lighting conditions.
Analog Input Totalizer
The analog input totalizer function allows the Panel Meter to accumulate analog signal values over time, providing cumulative data essential for applications like tracking total flow in pipelines, total energy consumption, or material usage in production. Compatible with a range of analog inputs, such as 4-20 mA current loops or 0-10 V voltage signals, this totalizer offers flexibility to monitor various process parameters, enhancing operational insights and reporting accuracy.
Process Meter
As a process meter, this device excels at measuring and displaying a wide array of process variables, including temperature, pressure, flow, level, and more. By processing analog inputs and converting them into meaningful real-time data, the 1/8 DIN Panel Meter supports precise monitoring and control, ensuring processes remain within specified parameters for optimal performance and safety.
How Does a 1/8 DIN Panel Meter Work?
The operation of a 1/8 DIN Panel Meter for analog input totalizer and process metering involves several key steps:
-
Signal Acquisition: The meter receives an analog input signal from a sensor or transducer, such as a pressure transmitter or flow meter, connected to its input terminals.
-
Signal Conditioning: Internal electronics condition the signal through amplification, filtering, or scaling to ensure it is within the meter’s operational range, minimizing noise and enhancing accuracy.
-
Analog-to-Digital Conversion: An Analog-to-Digital Converter (ADC) transforms the conditioned analog signal into a digital value, enabling precise processing and display.
-
Display and Totalization: The digital value is displayed on the 6-digit screen in real-time, with the totalizer function accumulating values over time for cumulative measurements.
-
Output and Integration: Many models offer programmable outputs, such as alarms, relays, or analog signals, and communication interfaces (e.g., RS-232, RS-485) for integration with control systems like PLCs or SCADA.
Key Features and Benefits
-
High Precision: The 6-digit display ensures accurate capture and presentation of even subtle changes in analog inputs, critical for precise process control.
-
Versatility: Supporting multiple analog input types, this Panel Meter is adaptable to industries like manufacturing, energy, water treatment, and HVAC, meeting diverse application needs.
-
Compact Size: The 1/8 DIN size enables easy integration into control panels without occupying excessive space, ideal for space-constrained environments.
-
Totalization Functionality: The totalizer accumulates analog input values over time, providing valuable data for operational analysis, inventory management, and regulatory compliance.
-
User-Friendly Interface: A clear, intuitive display and configurable settings allow operators to monitor and interpret process data efficiently, supporting rapid decision-making.
Conclusion
The 1/8 DIN Panel Meter for 6-Digit Analog Input Totalizer & Process Meter is a cornerstone of industrial automation, offering precise measurement, totalization, and display of analog inputs. Its compact design, high accuracy, and versatility make it indispensable for applications requiring reliable process monitoring and control. Whether in manufacturing, energy management, or environmental systems, this Panel Meter delivers exceptional performance, enhancing operational efficiency and safety.
Where Is a 1/8 DIN Panel Meter for 6-Digit Analog Input Totalizer & Process Meter Used?
The 1/8 DIN Panel Meter for 6-Digit Analog Input Totalizer & Process Meter is a specialized instrument widely utilized in industrial settings for monitoring, controlling, and totalizing process variables. Its compact size, precision, and adaptability make it a critical tool across various applications. Below, we explore the primary industries and use cases where this device is deployed.
1. Manufacturing and Production Facilities
- Process Monitoring: In manufacturing plants, maintaining precise control over processes like mixing, filling, or curing is essential. This Panel Meter monitors variables such as temperature, pressure, or flow rates, ensuring processes stay within specified limits to uphold product quality and efficiency.
- Totalization: The totalizer function tracks cumulative measurements, such as the total volume of materials dispensed in a batch process, aiding in inventory management and ensuring compliance with production targets.
2. Energy Management Systems
- Power Monitoring: In power plants and distribution networks, this Panel Meter tracks electrical parameters like current, voltage, or power consumption. It provides real-time data and totalized energy usage, supporting efficiency optimization and cost reduction.
- Sub-Metering: In large industrial or commercial complexes, sub-metering allocates energy costs to specific departments or tenants. The meter’s totalizer function records energy consumption for individual systems, offering detailed usage insights.
3. Water and Wastewater Treatment Plants
- Flow and Level Monitoring: Accurate monitoring of water flow and levels is crucial in treatment facilities. This Panel Meter displays and totalizes flow rates, ensuring proper management of water processing stages and compliance with environmental regulations.
- Chemical Dosing Control: For precise dosing of chemicals like chlorine or pH adjusters, the meter monitors flow or concentration levels, ensuring safe and effective treatment processes.
4. Automation and Control Systems
- Integration with PLCs and SCADA: In automated environments, this Panel Meter integrates with Programmable Logic Controllers (PLCs) and Supervisory Control and Data Acquisition (SCADA) systems, providing a reliable interface for real-time process control and monitoring.
- Alarm and Signal Conditioning: Equipped with alarm outputs and signal conditioning, it supports critical applications by alerting operators to out-of-range conditions, enabling prompt corrective actions.
5. HVAC Systems
- Environmental Control: In large buildings or industrial facilities, HVAC systems require precise control over temperature, humidity, and airflow. This Panel Meter monitors and totalizes key parameters, ensuring efficient operation and comfortable indoor environments.
- Energy Efficiency: By tracking cumulative data, such as airflow or coolant volume, the meter helps optimize HVAC performance, reducing energy consumption.
6. Research and Development Laboratories
- Experimental Monitoring: In R&D settings, accurate data collection is vital. This Panel Meter monitors and totalizes variables during experiments, providing researchers with precise data for analysis and validation.
- Instrument Calibration: It supports calibration of other instruments, ensuring measurement equipment meets required standards for reliable results.
Conclusion
The 1/8 DIN Panel Meter for 6-Digit Analog Input Totalizer & Process Meter is a versatile and reliable tool essential for precise monitoring, control, and data accumulation in industrial applications. Its applications span manufacturing, energy management, water treatment, automation, HVAC, and research, making it a cornerstone for environments where accuracy and efficiency are paramount. With its compact design, high-precision display, and robust functionality, this Panel Meter ensures processes operate smoothly, safely, and within specified parameters.
Less Information.